Bosch VG5 600 Series User Manual page 61

Autodome 600 series analog ptz camera
Hide thumbs Also See for VG5 600 Series:
Table of Contents

Advertisement

AutoDome 600 Series Analog PTZ
Camera
Setting
Status
Mode
Interval
Initial Offset
Number of Recals Total number of homing recalibrations performed due to loss of home or
Next Cal
1.
2.
3.
4.
Bosch Security Systems, Inc.
Values
Enabled
Disabled
Loss
Loss + Interval
6 - 72 hours, in 6-hour increments
4 - 20 hours, in 4-hour increments
interval
Shows the days, hours, minutes, and seconds until the next homing
recalibration
Set the Recalibration Mode to recalibrate on the loss of home and after every interval:
Issue the AUX ON 682 command.
Issue the AUX ON 682 command again.
Note: The AUX ON 682 command must be issued twice only for the initial setup.
Each subsequent AUX ON 682 command toggles the mode as described in the table
above.
Set the Recalibration Interval by issuing the AUX ON 683 and the AUX OFF 683
commands. For example, to set the Recalibration Interval to 24 hours, issue the AUX ON
683 commands four times.
Set the Initial Offset Time by issuing the AUX ON 684 and the AUX OFF 684 commands.
For example, to set the Initial Offset Time to 8 hours, issue the AUX ON 684 command
twice.
Issue the AUX ON 681 command to enable the recalibration routine.
User Manual
Advanced Features | en
61
2014.11 | 2.1 | F.01U.270.005