7
Tab
Install ball end of downrod into mounting
bracket opening. Align (engage) slot on
ball with tab on mounting bracket.
Warning: Failure to align slot on ball with
tab may result in serious injury.
Important: If using the angle mount,
make sure open end of mounting bracket
is installed facing the higher point of the
ceiling and make sure the ceiling angle is
not steeper than 30º.
10
Grounded
wires
Receiver
After making the wire connections, the wires
should be spread apart with the grounded
conductor and the equipment-grounding
conductor on one side of the outlet box and
ungrounded conductor on the other side of
the outlet box. The splices after being made
should be turned upward and pushed carefully
up into the outlet box.
© 2015 Monte Carlo Fan Company
8
Lag screw
Safety cable
Slot
Washer
Lock washer
For Canadian installation and for USA fan
and light kit combinations over 35 lbs, in
both flush and downrod modes the safety
cable must be installed into the house
structure beams using 3" lag screws,
washers and lock washers provided.
Make sure that when the safety cable is
fully extended the lead wires are longer
than the cable and no stress is placed on
the lead wires.
Note
: If Installing The Secondary Support
Safety Cable in the U.S., Do Not Remove
Knockouts In The Outlet Box.
11
Ungrounded
Stud
wires
Lift Canopy allowing the 2 studs to protrude
through the canopy.
Next lift the cover ring and install knurled nuts
as shown. Tighten the knurled nuts securely.
The canopy should adjust for any irregularity
in the ceiling or Outlet box.
Make sure the studs protruding from the
bottom of the Mounting bracket are installed
with threads all the way through the bracket.
Go to step 20 to finish
installation
SAFETY CABLE INSTALLATION
4
9
Black
Wall switch
(Live)
White
(Neutral)
Ground/Green
Make wiring connections using wire
connectors provided as indicated above.
White from fan to White from remote
marked N. Black from fan to Black from
remote marked L. Blue from fan to Blue
from remote marked FOR LIGHT. White
from house to White from remote marked
AC IN N. Black from house to Black from
remote marked AC IN L. Connect all
green grounded wires to Grounded wire
from House. Make sure that no filaments
are outside of the wire connectors.
Insert the remote receiver into mounting
bracket.
Refer to page 7 for receiver
setting.

Flush Mount Installation

12
Remove every other screws from yoke
located on top of fan assembly. Keep
screws.
Note: Flush mount is not available with
vaulted ceiling.
White
Blue
Black
Receiver
Black
White
9/15/2015