1
Before you begin installing the fan, Switch
power off at Service panel and lock
service disconnecting means to prevent
power from being switched on
accidentally. When the service
disconnecting means cannot be locked,
securely fasten a warning device, such
as a tag, to the service panel.
Use AC 120V/60HZ power supply
only.

SAFETY CABLE INSTALLATION

4
Safety cable
Lag screw
Safety cable
Washer
Lock washer
For Canadian installation and for USA fan
and light kit combinations over 35 lbs, in
both flush and downrod modes the safety
cable must be installed into the house
structure beams using 3" lag screws,
washers and lock washers provided.
Note
: If Installing The Secondary Support
Safety Cable in the U.S., Do Not Remove
Knockouts In The Outlet Box.
© 2020 Monte Carlo Fan Collections
2
Ceiling
Ceiling
Joists
Before installing this fan makes sure the
outlet box is properly installed to the
house structure. Ensure the outlet box is
securely fastened by at least two points
to a structural ceiling member (a loose
box will cause the fan to wobble).
To reduce the risk of fire, electric shock,
or personal injury, mount to outlet box or
supporting system acceptable for fan
support.
(Mounting must support at least 35 lbs.)
5
Junction
Box
Mounting
Blade supporting
Bracket
plate
STOP: Do not install blade set screws unless
blade and blade supporting plate are in place.
Doing so will damage the motor and void the
warranty.
Place motor assembly on bottom Styrofoam
for blades installation.
Aligning the holes on blade, blade supporting
plate (Place it on the blade) and the screw
holes on motor as shown in illustration, and
then partially install the set screws. Screws
provided. Repeat this process for remaining
blades.
Tighten all set screws securely after all the
blades are installed to motor.
Install decorative cap onto motor shaft by
turning clockwise until tight.
3
2˝ x 4˝
Outlet
Box
Partially loosen 2 of the set screws on mount -
ing bracket corresponding to the slotted holes
on the canopy upper ring. Remove the other 2
set screws. Save screws.
Use metal outlet box suitable for fan
support and use only the screws provided
with the outlet box (must support 35 lbs).
Remove the two outlet box screws
provided with the box, aligning the holes
of the mounting bracket with the holes of
the outlet box. Reinstall the 2 outlet box
screws securely.
6
Keeper
pin
Decorative cap
Blade
Flip the motor assembly with blades over.
Partially loosen downrod set screws from
yoke at top of motor assembly.
Remove preassembled cross pin and
keeper pin from downrod.
3
Ceiling joist
Outlet Box
Mounting
Bracket
Screw/ Washers
/Spring Washers
Downrod
Yoke
Cross
pin