Application:
TM
devireg
610 is an electronic thermostat designed for
regulating heating and cooling, from -10
TM
devireg
610 is moisture proof (IP44).
TM
devireg
610 has a built-in 2-pole switch, so an external
switch is not necessary.
devireg
TM
610 is supplied with a NTC sensor of 2.5m
cable. The sensing cable can be extended by up to 50m,
using 1.5mm cable, without affecting the accuracy of the
thermostat. However, the cable must not be placed parallel
to high voltage cables. This is to prevent undesirable
signals being induced. The installation must be permanent.
The thermostat must be connected by a qualified
electrician.

Installation:

1. Before opening the thermostat cover, set the adjustment
button to the minimum temperature, 0
2. When installing in bathrooms etc., a minimum distance
to hazardous locations must be observed and must comply
with current regulations for electric installations.
3. The stamped punchings for cable glands can be
removed using a screwdriver and hammer.
4. The thermostat should be mounted vertically on a wall.
The screw holes must be sealed with the enclosed plugs.
5. If the sensor is to be built-in or exposed to pressure it
should be placed in a protective tube.
6. Wire connection according to circuit diagram, fig. 1 or 2.
Select which function is required (Heating/Cooling).
7. After closing the thermostat cover, check that
adjustment button can be adjusted within full temperature
range, i.e. -10
o
o
C to +50
C.
o
o
C to +50
o
C.
C.