    Placement of Devireg™ 530, 531, and 532 ......7 Connection diagrams for Devireg™ 530, 531, and 532 ..8 Technical specifications for Devireg™ 530, 531, and 532 ..............9 The DEVI™ Guarantee ..............10-11 The installation must only be carried out by an authorised electrician.
  • Page 3: Applications And Functions

    Table of content 1. Applications and Functions The Devireg™ 530 series is a line of electronic thermostats used for control of indoor heating. The Devireg™ 530 is used for control of floor heating installations. The thermostat is equipped with a floor sensor for control of the desired floor temperature.
  • Page 4: Maximum Floor Temperature Setting

    2. Maximum floor temperature setting Maximum floor temperature is preset at the factory to 35°C for cable temperature safety. Local building regulations must be observed when changing the maximum preset tempera ture. You can/must set the maximum floor tempera ture on the Devireg™ 532 by taking off the front cover and with a screwdriver adjust the sunken temperature dial in the top left hand corner between 20°...
  • Page 5: Light Indications (Led)

    3. Light indications (LED) The Devireg™ 530 series has a LED indicator above the 2 pole safety switch (see illustration). indicator devireg™550 The LED has four indications: • No light means the system is off. • Red light means system is heating. •...
  • Page 6: Installation Instructions

    4. Installation instructions When installing a thermostat from Devireg™ 530 series, you must first remove the front cover. To remove the front cover, gently press the release tabs under the bottom of the thermostat with a screwdriver. Then remove the front. You do not need to remove the set point dial.
  • Page 7: Placement Of Devireg™ 530, 531, And 532

    5. Placement of Devireg™ 530, 531, and 532 Installation height, typically between 80-150 cm for Devireg 531/532 In wet rooms it should be installed on an even surface, according to local building regulations. At least 50 cm away from windows/doors that will be left open occasionally.
  • Page 8: Connection Diagrams For Devireg™ 530, 531, And 532

    Configuration - Max. floor temp. Max.Load 15 A Devireg™ 530 Type D530 LOAD LOAD 5-45°C Max.Load Devireg™ 531 15 A Type D531 NC = LOAD LOAD no connection 5-35°C Max.Load 15 A Devireg™ 532 Type D532 Temperature limiter LOAD LOAD NC = 20-50°C no connection...
  • Page 9: Technical Specifications For Devireg™ 530, 531, And 532

    8. Technical specifications for Devireg™ 530, 531, and 532 Operation voltage 180-250 VAC, 50/60 Hz Standby consumption Max. 0.25W Relays: • Resistive load 230V ~ 15A/3450W • Inductive load cos φ = 0.3 Max. 4A Sensing unit NTC 15 kOhm at 25°C Sensing values: •...
  • Page 10: The Devi™ Guarantee

    All work will be invoiced in full if DEVI is required to inspect or repair faults that have arisen as a result of any of the above.
  • Page 11 2 YEAR WARRANTY Warranty Certificate The DEVI Guarantee is granted to: Name: Address: City: Country: Telephone: Attention: The Warranty Certificate must be completed correctly for the Warranty to be valid. Please read the Warranty conditions on the previous page. Type of thermostat:...
  • Page 12 Article No.: 08095821 Version - 02.05 DEVI A/S Ulvehavevej 61 DK-7100 Vejle Tel: +45 74 88 85 00 Fax: +45 74 88 85 01 www.devi.com...