electrical Information

This Micro System is fitted with a BS1363/A 13 amp plug. If it is not suitable for your
supply sockets it must be removed and replaced with an appropriate plug. If the plug
becomes damaged and/or needs to be replaced please follow the wiring instructions
below. The plug removed must be disposed of immediately. It must not be plugged
into a supply socket as this will be an electrical hazard. If the fuse needs to be
replaced it must be of the same rating and ASTA approved to BS1362. If the plug is
changed, a fuse of the appropriate rating must be fitted in the plug, adapter or at the
distribution board. If the fuse in a moulded plug is replaced, the fuse cover must be
refitted before the appliance can be used.
Wiring Instructions
The supply cable will be either 2-core or 3-core. Follow the appropriate wiring
instructions given below. In both cases ensure that the outer sheath of the cable is
firmly held by the cable clamp.
2- Core plug
WARNING: Do not connect either wire
to the earth terminal.
This symbol indicates that this 2-core appliance
is Class II and does not require an earth
connection.
The wire coloured blue must be connected to the
terminal marked with the letter N or coloured black.
The wire coloured brown must be connected to the
terminal marked with the letter L or coloured red.
Blue
(Neutral)
22
3- Core plug
The wire coloured green and yellow must be
connected to the terminal marked with the letter E, or
by the earth symbol
and yellow.
The wire coloured blue must be connected to the
terminal marked with the letter N or coloured black.
The wire coloured brown must be connected to the
terminal marked with the letter L or coloured red.
Green & yellow
Fuse
(Earth)
Brown (Live)
Blue
(Neutral)
WARNING: This appliance must be earthed.