2.1) Operating limits (912 A/F/UL)

Performance

Speed

Acceleration

Oil pressure

Oil temperature

EGT

Effectivity: 912 A/F/UL
OM Edition 2 / Rev. 0
Performance data relate to ISA (International Standard Atmo-
sphere) conditions without Governor, external alternator etc.
Take-off performance
Max. continuous performance
Take-off speed
Max. continuous speed
Idle speed
Limit of engine operation at zero gravity and in negative "g" con-
dition.
Max.
Max.
NOTICE
Min.
Normal
Max.
Min.
normal operating temperature
exhaust gas temperature
Max.
BRP-Powertrain
59.6 kW at 5800 rpm
58 kW at 5500 rpm
5800 rpm (max. 5 min)
5500 rpm
min. 1400 rpm
5 seconds at max. -0.5 g
7 bar (102 psi)
For a short period admissible at cold start.
0.8 bar (12 psi) (below 3500 rpm)
* 1.5 bar (22 psi)
2.0 to 5.0 bar (29-73 psi) (above
3500 rpm)
* 1.5 to *5.0 bar (22-73 psi)
* 912 UL to S/N 4,402.387
912 A
912 F
140 °C (285 °F)
50 °C (120 °F)
approx. 90 to 110 °C (190 - 230 °F)
880 °C (1616 °F)
to S/N 4,410.266
to S/N 4,412.764
page 2-2
April 01/2010