5. STORAGE

5.1. Before storing for a prolonged period of time carry out the following;
5.1.1. Turn off the power supply.
5.1.2. Disconnect the power lead from the power supply.
5.1.3. Pull the relief valve and release all air pressure form the tank.
5.1.4. Drain compressor as in 4.1 above.
5.1.5. Clean the air compressor to remove all dirt and dust.
5.1.6. Cover the air compressor with a cover to protect the unit from dust and moisture,
make sure compressor is cold before covering.
5.1.7. Do not stack or store any items on top or around the air compressor, otherwise
damage may occur.
6. TROUBLESHOOTING
6.1. If you are experiencing a problem that is not listed in this chart, or have checked all possible
causes listed and you are still experiencing problems please contact your dealer.
Problem
Pressure drops in
Air leaks at connections.
the tank.
The solenoid
valve leaks when
the compressor is
idle.
The compressor
stops and does
not restart.
Motor winding are burnt
The motor does
not start and
Capacitor is burned out.
makes a
humming noise.
The motor does
Low voltage supply to the
not start or starts
slowly.
The compressor is
Compressor head gasket
noisy with
metallic clangs.
Possible Causes
Non-return valve seal
defective.
Overload cut-out
operated because of
motor overheating.
out.
motor.
broken of faulty valve.
Let the air compressor build up pressure in the tank, to
the maximum pressure. If possible brush soapy water on
air connections and look carefully for air bubbles.
Tighten leaky connections. If problem persists contact
your dealer for further advice.
Let the air in the tank flow out until all pressure is
released. Then remove the no-return valve plug and
clean the valve seal. If necessary replace the seal and
then reinstall all components.
Check that the mains voltage corresponds to
specification. An extension cord that is too thin or too
long can cause a volt drop and cause the motor to
overheat. Allow motor to cool down. Use heavy duty
extension leads. Make sure the compressor is plugged
into a socket as close to the supply as possible.
Contact your dealer.
Replace starter capacitor.
Check that the mains voltage corresponds to
specification. An extension cord that is too thin or too
long can cause a volt drop and cause the motor to
overheat. Allow motor to cool down. Use heavy duty
extension leads. Make sure the compressor is plugged
into a socket as close to the supply as possible.
Stop the compressor and contact your dealer.