Download Print this page

Installation & Earthing - Hyundai HY0808 User Manual

Oil-less

Advertisement

3. INSTALLATION & EARTHING
3.1. Installation.
3.1.1. The compressor must be used on a stable and level surface. The air compressor must
be used in a clean and well ventilated area. The compressor requires an unobstructed
airflow and must be located a minimum of 450mm from any wall or other obstructions.
3.2. Earthing instructions
3.2.1. This product should always be used with the earth wire connected. In the event of
an electrical short circuit the earth wires reduces (but does not eliminate) the risk of
electric shock.
3.2.2. This product is for use on a 230 VAC 50 Hz supply.
3.2.3. This product is supplied with a cord incorporating an earth wire it must be connected
to an earthed socket. It is highly recommended that you use a socket outlet that has
Residual Current Device RCD. When connected to an
RCD outlet it will protect user/s against electric shock.
3.3. Extension Leads.
3.3.1. We do not recommend the use of an electrical extension lead with this product as
this may result in loss of power and overheating of the motor.
3.3.2. Additional air hoses should be considered before an electrical extension lead.
3.3.3. If the use of an extension lead is unavoidable then use only suitable extension leads
which incorporate an earth connection.
3.3.4. Improper use of an extension lead can cause inefficient operation of the motor/air
compressor which can result in overheating.
3.3.5. Suggested extension lead cable sizing.
Extension lead length
Up to 7.5 m
7.6 m to 15 m
15.1 m to 30 m
Improper installation of the earth connection can result in a risk of
electric shock.
If repair or replacement of electrical cable is necessary do not
connect the earth wire to either the live or neutral pins.
Brown is Live – Blue is Neutral – Green/Yellow striped is Earth.
If in doubt consult a qualified Electrician.
Page 10
Wire size
2
2.5 mm
2
4.0 mm
2
6.0 mm
Ver 2

Advertisement

loading

This manual is also suitable for:

Hy0816