ATTO Technology Diamond Storage Array VT-Class Installation And Operation Manual page 94

Diamond storage array
Table of Contents

Advertisement

Safe handling of the Diamond-VT will help protect its components as well as the people working with them.
• The Diamond-VT is heavy (92 pounds for the
floor model, 86 pounds for the rack mount
system). Two people will be needed to move it
safely.
• Mechanical, shock and energy hazards are
present through the system if one or more of the
modules is removed. There are no operator-
serviceable components inside the unit except
Hardware Maintenance
those indicated in
Hot Swap Operating Instructions
67 and
69of this manual.
CAUTION
CAUTION
All modular components must be replaced
by qualified personnel only.
• This equipment must be connected to a
protective earth ground in accordance with the
instructions provided in this guide. Improper
grounding may result in an electrical shock.
• When the power supply
Power Switch Positions
On
Stand-by
AC power cord from the back of the unit from
both power supply inputs. The switch on the
power supply is only a standby switch and does
not disconnect the AC from the system.
Radio and television interference
WARNING
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a commercial environment. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
A-xiii
ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual
Appendix F Product Safety
on page
on page
green LED is on, the power
source is fully operational,
delivering power to the
system. The only way to
completely disconnect from
the system is to remove the
• This unit is designed to only have inside
communication lines connected to it (no lines
outside the building proper).
• The Diamond-VT must be provided with
adequate air flow. To reduce the risk of damage,
the ambient temperature of the inlet air should
o
not exceed 40
C.
• Service personnel must follow proper grounding
methods when working with or around the
system because of the Diamond-VT's
electrostatic sensitive components. Use a static
wriststrap when handling any components from
the Diamond-VT.
Safety compliances
• UL 1950 3rd Edition
• CSA 22.2 No. 950-95
• LEDs and fibre GBIC are Class 1 Laser Rated
EMC specifications
• EN 55022: class A
• EN 50204 RF Immunity 900 MHz Pulse
• EN 61000-4-8 Magnetic Immunity
• EN 61000-4-2: ESD
• EN 61000-4-3: Radiated Immunity
• EN 61000-4-4: EFT
• EN 61000-4-5: Surge
• EN 61000-4-6: Conducted Immunity
• EN 61000-4-11: Voltage Dips and Interruptions