6.6 Maintenance Services Commands
Maintenance commands allow updating and maintenance of the Diamond-VT.
FcScsiBusyStatus
You may set the Diamond to report busy or queue full
when it is unable to accept a command.
Default: Busy
Set syntax: set FcScsiBusyStatus [busy|qfull]
FirmwareRestart
Causes a warm restart of the Diamond Storage Array
Immediate command: FirmwareRestart
MaxEnclTempAlrm
Sets/displays the maximum enclosure temperature alarm
of the Diamond Storage Array in degrees Celsius. Valid
entries are between 5 and 52 degrees and above the
current minimum enclosure temperature alarm
Default: 47
Set syntax: set MaxEnclTempAlrm [5-52]
Requires a SaveConfiguration command
Get syntax: get MaxEnclTempAlrm
MinEnclTempAlrm
Sets/displays the minimum enclosure temperature alarm
of the Diamond Storage Array in degrees Celsius.Valid
entries are between 5 and 47 degrees and below the
current maximum enclosure temperature alarm
Default: 5
Set syntax: set MinEnclTempAlrm [5-47]
Requires a SaveConfiguration command
Get syntax: get MinEnclTempAlrm
ResolveLUNConflicts
Re-numbers any conflicting Logical Unit numbers that
exist in the Diamond. Conflicts may occur when a unit is
taken from one Array and inserted into another Array.
Immediate command: ResolveLUNConflicts
RestoreConfiguration
Restores configuration to either the default configuration
or the configuration last saved into non-volatile memory.
The saved option will undo any changes made since the
last save.
Immediate: RestoreConfiguration [Default|Saved]
SaveConfiguration
If the restart option is selected, the Diamond will cycle its
power. The norestart option will save changes without
restarting. Please note: certain modifications require a
command and a system restart. If
SaveConfiguration
required, the return
Ready. *
return for the modification. You may make several
changes through commands and
before implementing a restart, but once you have
restarted the Diamond, all the command changes created
before the restart and saved will be implemented.
or
parameter is optional
Restart
no Restart
Immediate: SaveConfiguration <Restart| NoRestart>
SpeedWrite
SpeedWrite is a method to improve the performance of
FCP WRITE commands to SCSI devices attached to the
array.
Default: disabled
Set syntax: set SpeedWrite [enabled | disabled]
Requires a SaveConfiguration Restart command
Get syntax: get SpeedWrite
Temperature
Returns the current internal temperature of this Diamond
Storage Array in degrees Celsius. The value is read only.
Get syntax: get Temperature
Zmodem
Use the Zmodem protocol to transfer a file to or from the
Diamond Storage Array. The filename is required if the
'send' option is specified. Available only through the RS-
232 interface
CAUTION
CAUTION
After a firmware image is downloaded to
the Diamond Storage Array, the image is
placed into flash memory. During this time
(about 90 seconds), DO NOT remove power
to the Diamond Storage Array or the flash
may become corrupted. Power should not
be removed until the READY prompt
appears.
Immediate command: Zmodem [Send filename|Receive]
ZoneRetrieve
Retrieves the Active Zone Configuration into the Planned
Zone Configuration to allow modifications of the current
configuration.
Zone syntax: ZoneRetrieve
will be displayed after the
SaveConfiguration
38