ATTO Technology Diamond Storage Array VT-Class Installation And Operation Manual

Diamond storage array

Advertisement

Quick Links

Diamond Storage Array
VT-Class
Installation and Operation Manual
© 2005 ATTO Technology Inc. All rights reserved. All brand or product names are trademarks of their
respective holders. No part of this manual may be reproduced in any form or by any means without the
express written permission of ATTO Technology Inc.
2/05
6.4
PRMA-0341-000

Advertisement

Table of Contents
loading

Summary of Contents for ATTO Technology Diamond Storage Array VT-Class

  • Page 1 Installation and Operation Manual © 2005 ATTO Technology Inc. All rights reserved. All brand or product names are trademarks of their respective holders. No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO Technology Inc.
  • Page 4: Table Of Contents

    Command Line Interface ATTO ExpressNAV In-band SCSI over Fibre Channel RS-232 port Ethernet port SNMP 4.1 In-band CLI Over Fibre Channel ...17 I/O details 4.2 Serial Port Access ...19 4.3 Ethernet Access: Telnet and SNMP Protocols ...21 ATTO Technology Inc. Contents...
  • Page 5 5.0 ATTO ExpressNAV: Browser-based Interface ...23 Browser compatibility Opening an ExpressNAV session Navigating ExpressNAV 5.1 ExpressNAV Pages ...25 Status Ethernet SNMP Serial Port Fibre Channel Storage Management RAID Clear Data Logical Units Partitions Zoning Tape Volumes Tape Drives Move Medium Rebuild Configuration Advanced...
  • Page 6: Diagnostic Commands

    FcScsiBusyStatus FirmwareRestart MaxEnclTempAlrm MinEnclTempAlrm ResolveLUNConflicts RestoreConfiguration SaveConfiguration SpeedWrite Temperature Zmodem ZoneRetrieve 6.7 Diagnostic Commands ...39 AudibleAlarm DiamondModel DiamondName DriveCopyStatus DriveInfo FcNodeName FcPortInfo FcPortList FcPortName Help IdentifyDiamond Info LUNInfo PartitionInfo PowerAudibleAlarm RAID5ClearDataStatus RAIDRebuildStatus SerialNumber SledFaultLED SMARTData TapeDriveInfo TapeVolumeInfo ATTO Technology Inc.
  • Page 7 Temperature VirtualDriveInfo ZoneInfo ZoneState 6.8 Drive Management Commands ...41 ATADiskState AutoRebuild ClearDiskReservedAreaData DriveCopy DriveCopyHalt DriveCopyResume DriveCopyStatus DriveInfo DriveSledPower DriveWipe IdeTransferRate IdeWriteCache InquiryData LUNInfo LUNState MediumType PartitionInfo QuickTape RAID5ClearData RAID5ClearDataStatus RAIDInterleave RAIDHaltRebuild RAIDManualRebuild RAIDRebuildState RAIDRebuildStatus RAIDResumeRebuild RebuildPriority ResolveLUNConflicts RestoreModePages SledFaultLED TapeDriveInfo TapeVolumeBlockSize TapeVolumeInfo TapeWriteProtect...
  • Page 8 Specific situations and suggestions 9.2 Resetting Defaults ...63 Default Return to Default settings Factory Default 9.3 Rebuilding RAID Level 5 and 10 Configurations ...65 10.0 Hardware Maintenance ...67 10.1 Hot Swap Operating Instructions ...69 Disk Drives Power Supplies Blower Assemblies ATTO Technology Inc.
  • Page 9 Rack Mount Dimensions Floor Mount Dimensions Appendix F Product Safety ...xiii Safety compliances EMC specifications Radio and television interference Appendix G Part numbers ...xiv Appendix H Warranty ...xv Manufacturer limited warranty Contact ATTO Technology, Inc. Diamond Storage Array Installation and Operation Manual...
  • Page 10: Preface

    155 CrossPoint Parkway Amherst, New York 14068 (716) 691-1999 • voice (716) 691-9353 • fax http://www.attotech.com/diamond ATTO Technology can also be reached via e-mail at the following addresses: Sales Support: sls@attotech.com Technical Support: techsupp@attotech.com Manufacturer provides this publication as is,...
  • Page 12: Diamond Storage Array-Vt Product Overview

    Diamond-VT cabinet as technology progresses by simply replacing disk drive sleds and host interface cards. ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual The Diamond-VT is operating system independent and supports all popular computer hardware platforms and network environments.
  • Page 13: Fibre Channel Model

    • Aggregated Data Transfer Technology (ADXTJ) for high performance/scalability • Ultra ATA 100 megahertz (Mhz) • RAID Level 10 and RAID Level 5 configurable • Zoning capability compatible with third party servers, switches and with deliverables from industry standards organizations. •...
  • Page 14: Diamond-Vt Technical Overview

    2Gb FC or 400MB/sec Ultra160 Duplex SCSI Host ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual technology, to create a higher performance storage solution. Using this technology, we are able to provide a storage array that delivers faster sustained data transfer rates as well as impressive I/Os per second at a new price point in the storage market.
  • Page 15: Adxt Powers Ata To New Levels

    ADXT Powers ATA to New Levels The original notion of RAID was to build high capacity, reliable storage subsystems using large numbers of inexpensive disk drives. Thus its original definition: Redundant Array of Inexpensive Drives. Over time that definition became Redundant Array of Independent Drives and the inherent cost advantage in a RAID system was lost.
  • Page 16: Installation Instructions

    Step 2a: set up the Ethernet connection The Diamond-VT supports service operations over the RS-232 serial port using standard ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual terminal emulation software available with most systems. Connect a DB-9 null modem serial cable between the port marked RS-232 on the front of the Diamond-VT and the computer’s serial port.
  • Page 17: Step 3: Set Up Virtual Tape Configuration

    Follow the screens to find information about the array or to configure the array from the factory- default settings. The Diamond-VT may be set up in a RAID Level 5 or RAID Level 10 configuration with or without Hot Spare sleds and/or set up in a zoned configuration.
  • Page 18: Diamond-Vt Components

    A and B installation status, and the power status for each power supply. ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual rear of the unit holds the host interface cards, power supplies and blower assemblies.
  • Page 19: Rack Mount Model

    Rack mount model The system management card is at the left front of the case. At its center is a DB-9 serial RS-232 port which allows a connection for setup, monitoring and upgrade of the unit from any computer system with an RS-232 interface.
  • Page 20: Diamond-Vt Physical Setup

    The holes accommodate 10/32 screws but the screws can protrude no farther than .375 inches into the rack. ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual Spaced rail pairs in some rackmount cabinets. You can mount the Diamond-VT using two sets of...
  • Page 21: Rack Mount

    General Instructions Insert the proper connector into the Host Interface Card in the back of the Diamond-VT. Connecting a Fibre Channel Array (See 11 or Connecting a SCSI Array Connect the cable (Fibre Channel or SCSI) from your host system to the Host Interface Card connector on the back of the Diamond- VT.
  • Page 22: Connecting A Fibre Channel Array

    However, if ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual one port in a HIC is connected into a point-to- point topology, the other port cannot be used.
  • Page 23 Exhibit 3.2.1-2 Possible 2 gigabit Fibre Channel physical connections depending on which Fibre Channel connection mode has been selected. point-to- point mode loop mode Diamond Storage Array A loop loop connection mode mode possible loop loop loop daisy-chain mode mode mode Diamond Storage Array B Fibre Channel connections...
  • Page 24: Connecting A Scsi Array

    Ultra 3 or Ultra160 SCSI Exhibit 3.2-2SCSI interface cards: left without terminators attached; right with a terminator attached. ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual or connect a cable between the second connector and the next device on the SCSI bus.
  • Page 25 SCSI connections...
  • Page 26: Accessing The Diamond-Vt

    Refer to ATTO ExpressNAV: Browser-based Interface on page 23 for more information on the program. ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual In-band SCSI over Fibre Channel In-band SCSI commands (Write Buffer and Read Buffer) may be issued to the Diamond-VT Fibre...
  • Page 27: Snmp

    Exhibit 4.0-1 The POST information displayed after boot of the Diamond-VT. Initialization Complete Diamond Storage Array (c) 2004 ATTO Technology, Incorporated. Firmware version A21R release date Apr 30 2004, 11:14:42 Build A21R Power-On Self-Test Completion Status: GOOD 128 Megabytes of RAM Installed.
  • Page 28: In-Band Cli Over Fibre Channel

    This buffer is 8 KB and circular. Retrieve the results by issuing a Read Buffer command before issuing another Write Buffer command. ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual A subsequent Write Buffer command executes the new command line and overwrites the previous results in the buffer with new results.
  • Page 29 to an initiator that specifies an incorrect Buffer ID, Mode, Length or Buffer Offset. The Mode is Exhibit 4.1-2 The SCSI command process: reserve the Diamond-VT, send the command, release the Diamond-VT. Initiator/Host Goal: reserve the Diamond-VT for an in-band CLI command SCSI cdb: Reserve LUN 0 Goal: retrieve the Diamond-VT temperature via in-band CLI 1.
  • Page 30: Serial Port Access

    Windows HyperTerminal. Set the emulator to use the COM port with cable attached, then the following settings • 115200 baud ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual • 8 bit ASCII • no parity • ASCII terminal type •...
  • Page 31 Serial port access...
  • Page 32: Ethernet Access: Telnet And Snmp Protocols

    DHCP, you may enable automatic IP addressing (set IPDHCP enabled) using the CLI. Open a Telnet session on the host computer. ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual • IP address • Port type: telnet • Terminal type: vt100...
  • Page 33 Warranty Call technical support (see Appendix, page xv) to get the appropriate MIB file for your Diamond-VT. For each client, copy the MIB file to the directory containing the SNMP management software. 10 From within the SNMP management software, compile the file attodmnd-mib.mib according to the software’s procedures.
  • Page 34 You may also go back one page or go to the Home page via the titles on the left side of the page. ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual Minimum requirement is for Internet Explorer 5.5 and Netscape 6.2.
  • Page 35 Exhibit 5.0-3 Navigating ATTO ExpressNAV screens Information required to perform changes Sidebar: select the item you wish to view options Parameter name Submit button Reset button Red print provides same as typing all return to previous link to help text CLI commands and setting without saveconfiguration...
  • Page 36: Baud

    • Full duplex mode • Connection mode See Connecting a Fibre Channel Array on page 11 for more information. ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual Storage Management Displays information about the drives and their status including •...
  • Page 37 Logical Units Displays information on the logical units which have been configured and allows you to change the status from online or offline or degraded. Partitions Displays the current configuration of the Diamond-VT including • Partition ID • Virtual Drive ID •...
  • Page 38 Screen messages, also called returns, may be either terse, with just the current information, or verbose, with labels and the current information. Default is verbose. If you want the terse mode, type set VerboseMode disabled. ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual command or by using a SaveConfiguration separate command.
  • Page 39 Exhibit 6.0-2 Symbols, typefaces and abbreviations used to indicate functions and elements of the Command Line Interface Symbol Indicates Required entry < > Optional entry pick one of … Ellipses, repetition of preceding item end of line a range (6 – 9 = 6, 7, 8, 9) Boldface words must be typed as they appear Italicized words...
  • Page 40 FcPortInfo FcPortList FcPortName FcSCSIBusyStatus FcWWName FirmwareRestart FTPPassword Help IdentifyDiamond IdeTransferRate ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual Defaults Online set AtaDiskState 6 1 offline Disabled set AudibleAlarm disabled set AutoRebuild enabled ClearDiskReservedArea 8 2 Diamond get DiamondModel “...
  • Page 41 Command IdeWriteCache enabled Info InquiryData IPAddress 10.0.0.1 IPDHCP Disabled IPGateway 0.0.0.0 IPSubnetMask 255.255.255.0 LUNInfo LUNState Online MaxEnclTempAlrm MediumType 0x85 MinEnclTempAlrm PartitionInfo PowerAudibleAlarm QuickTape RAID5ClearData RAID5ClearDataStatus RAIDHaltRebuild RAIDInterleave RAIDManualRebuild RAIDRebuildState RAIDRebuildStatus RAIDResumeRebuild RebuildPriority same ResolveLUNConflicts RestoreConfiguration RestoreModePages SaveConfiguration SerialNumber SerialPortBaudRate 115200 SerialPortEcho Disabled SerialPortHandshake...
  • Page 42 ZoneAddPort ZoneClearAll ZoneCommit ZoneCreate ZoneDelete ZoneInfo ZoneRemoveDevice ZoneRemoveHost ZoneRemovePort ZoneRetrieve ZoneState ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual Defaults get systemsn TapeDriveInfo set TapeVolumeBlockSize 2 TapeVolumeInfo Disabled set TapeWriteProtect enabled diamond set TelnetPassword 123ABC Disabled set TelnetTimeout 360...
  • Page 43 6.2 General Use Commands The following commands, listed alphabetically, describe or perform general functions. FirmwareRestart Causes a warm restart of the Diamond Storage Array. Immediate: FirmwareRestart Help Displays a list of available commands. Type ‘help’ followed by a command name to display detailed command-specific information.
  • Page 44 Default IP Address: 10.0.0.1 Set syntax: set IPAddress xxx.xxx.xxx.xxx Get syntax: get IPAddress Requires a SaveConfiguration command ATTO Technology Inc. IPDHCP Selecting DHCP allow the Diamond Storage Array to request an IP address from the network. It requires that the Diamond be attached to a network with at least one DHCP server.
  • Page 45 SNMPTraps Enables or disables SNMP traps. Default: disabled Set syntax: set SNMPTraps [enabled|disabled] Requires a SaveConfiguration Restart command Get syntax: get SNMPTraps SNMPUpdates Enables or disables the SNMP Management Information Base (MIB) database. Default: disabled Set syntax: set SNMPTraps [enabled|disabled] Requires a SaveConfiguration Restart command Get syntax: get SNMPUpdates TelnetPassword...
  • Page 46 FcFullDuplex Enable to allow full duplex Fibre Channel communication between the Diamond Storage Array and ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual host devices. Disable FcFullDuplex causes half duplex mode. Applies to both Fibre Channel ports Default: enabled...
  • Page 47 FcPortList Lists the status of all available Fibre Channel ports. Immediate command: FcPortList FcPortName Returns the Fibre Channel port name stored in NVRAM for this Fibre Channel port. Get syntax: get FcPortName [port number] FcScsiBusyStatus Specifies the SCSI status value returned when the Diamond is unable to accept a SCSI command because of a temporary lack of resources.
  • Page 48: Stop Bit

    Default: disabled Set syntax: set SerialPortEcho [enabled | disabled] Requires a SaveConfiguration Restart command Get syntax: get SerialPortEcho ATTO Technology Inc. SerialPortHandshake Describes which handshaking method the Diamond Storage Array uses for its terminal interface (hardware, Xon/Xoff or none). Choices are...
  • Page 49 6.6 Maintenance Services Commands Maintenance commands allow updating and maintenance of the Diamond-VT. FcScsiBusyStatus You may set the Diamond to report busy or queue full when it is unable to accept a command. Default: Busy Set syntax: set FcScsiBusyStatus [busy|qfull] FirmwareRestart Causes a warm restart of the Diamond Storage Array Immediate command: FirmwareRestart...
  • Page 50 Fibre Channel port. The status field indicates ‘disabled’ when a port has been internally disabled. Immediate command: FcPortInfo ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual FcPortList Lists the status of all available Fibre Channel ports. Immediate command: FcPortList...
  • Page 51 PowerAudibleAlarm Silences the audible alarm for a current power supply failure. The alarm will be activated on the next power failure. Immediate command: PowerAudibleAlarm disabled RAID5ClearDataStatus Displays the status of RAID5 Clear Data processing. S represents the sled number, D represents the drive number.
  • Page 52 (1-2). Immediate command: ClearDiskReservedAreaData [sled number] [drive number] ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual DriveCopy Copies a drive from the source disk to the destination disk. Parameters are the sled and drive numbers of the source and destination drives.
  • Page 53 DriveWipe Initializes a drive: wipes it of all data. Drive must be offline Set syntax: DriveWipe [Destination Sled] [Dest Drive] Requires a SaveConfiguration Restart command Get syntax: DriveCopyStatus Specifies or displays whether ECC is enabled or not. If ECC is not available, an ECC invalid returned.
  • Page 54 RAIDInterleave options are 16, 32, 64, 128, 256 blocks and span. Span is not available for RAID Level 5. For ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual RAID Level 10, choices are 16, 32, 64, 128, 256 or SPAN.
  • Page 55 RebuildPriority Sets the priority of a RAID Level 5 or 10 rebuild. If you select High priority, rebuild I/O requests are implemented before system I/O requests. I f you select Low priority, rebuild I/O requests executes only when there are no pending I/O requests.
  • Page 56 Removes one or more LUNs (devices) from an existing zone. To complete this procedure, the ZoneState ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual command must be entered as enabled to activate the zone before using the ZoneCommit command (which makes the Planned Zone Configuration the Active configuration).
  • Page 57 CLI: configure drives...
  • Page 58 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual other end to make sure the transmission has not had any errors.
  • Page 59 Advanced CLI configuration page of the ExpressNAV interface. Zoning supports security by granting or denying access between initiators and devices as defined by an administrator. A zone is a collection of devices which can access each other. The devices in a zone usually include one or more initiators, one or more devices, and one or more paths between the initiators and the devices.
  • Page 60 50 for more information and examples. You may specify the first four to six alpha- numeric characters of a tape bar code, used by ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual 7.1 Virtual Tape tape backup software. The remaining four characters will be entered by the system automatically to identify the tape number.
  • Page 61 7.2 Optional Hot Spare Sled To maintain array up time with minimal risk of data loss, individual sleds which fail may be replaced with a spare sled. In most configurations, if a member of a virtual device becomes degraded, you must swap out the faulted sled as defined in Hot Swap Operating on page 69.
  • Page 62 The host portion from a host through a port to a device (LUN), representing the Initiator ID in a SCSI ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual 7.3 Zones environment or the World Wide Port Name in a Fibre Channel environment.
  • Page 63 the Active configuration will be copied into the Planned configuration. To determine what is in the Planned configuration, type ZoneInfo Planned is persistent and establishes Active configuration the Diamond zoning configuration after power- The Planned configuration becomes the Active configuration after successful execution of the command.
  • Page 64: Configuring Zoning

    Configuring Zoning CAUTION CAUTION Be careful when changing Diamond-VT zoning configurations. Internal validation logic cannot detect misconfigurations An unrestricted zone configuration, exactly mimicking the LUN configuration, is created internally after the first power-up or restart after installation of the Diamond-VT. No special operating modes are required and Zoning can be easily installed with no impact on previous configurations.
  • Page 65 Errors The Zone commands Zone definition tables: manage entries in the Zone definition tables which manage the overall zoning process. Definition tables are indexed by unique keys ). All definition tables are zone_name repositories for their respective data and participate in establishing the configuration by executing the command.
  • Page 66: You Should Now Be In The Command Line

    • a crossover network cable for a direct connect or standard network cable if attached to a network device ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual Accessing the Diamond-VT In the Send File box, enter the current Diamond flash (“...”.ima) filename or click the...
  • Page 67 Copy the latest Diamond-VT image file (“...”.ima) onto the host computer and note its directory c:\diamond\flash\“...”.ima Change directories to the place where you copied the “...”.ima file cd c:\diamond\flash Open an FTP session using a user-defined IP address or the default (10.0.0.1) if it has not changed.
  • Page 68 The Ready LED (RDY) indicates the Ready LED operational status of the Diamond-VT. ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual One tool to At power up, the green Diamond Array Ready (RDY) LED is disabled until successful completion of the POST (Power On Self Test) indicating the array is ready for normal operation.
  • Page 69 temperature warning alarm will report OK during normal operating conditions. In an abnormal operating condition, such as blower failure, under high ambient temperatures when the Diamond internal midplane temperature reaches a critical point, the temperature alarm will report and activate the audible alarm and Warning fault LED on the front of the unit.
  • Page 70 an error code, please provide both the first and second blink code values. During a fault condition, more detailed information about the fault may be available via the CLI or the ExpressNAV interface over the RS- 232 interface port or the optional Ethernet port. These error messages should be reported to technical personnel to assist in debugging the problem.
  • Page 71 Monitoring, reporting...
  • Page 72: Troubleshooting

    Ethernet port. The blink codes are saved internally by the array to NVRAM and are displayed at power up. ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual 9.1 Troubleshooting Command Line Interface messages ERROR. Wrong/Missing Parameters...
  • Page 73 • Follow the instructions in the appropriate chapters of this manual to remove, replace and reconfigure the drive such as Instructions on page 69. • You may copy drives by using Command Line interface commands. Refer to Commands on page 41. If a power supply fails •...
  • Page 74: Resetting Defaults

    FirmwareRestart Type or cycle power of the Diamond-VT. ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual Reboot the host PC after the Diamond-VT completes its power on cycle. Factory Default Resetting the Diamond-VT to factory defaults is a last- ditch effort to recover from corrupt configurations or complete failure.
  • Page 75 Exhibit 9.2-2 Configurations which will be changed during a RestoreConfiguration command Command Default AudibleAlarm Disabled AutoRebuild Disabled DiamondName “...” EthernetSpeed Auto FcConnMode Loop FcDataRate Auto FcFairArb Enabled FcFrameLength 2048 FcFullDuplex Enabled FcHard Disabled FcHardAddress 0x03 IdentifyDiamond Disabled IdeTransferRate IPAddress 10.0.0.1 IPDHCP Disabled IPGateway...
  • Page 76 RAIDRebuildStatus enable the array rebuilds the degraded AutoRebuild. drives automatically when a new drive is inserted. ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual Note Drive rebuilding reduces performance. You may AutoRebuild want to leave disabled and manually rebuild during off-peak hours, or use the described below.
  • Page 77 To synchronize mirrored drives manually The most efficient method to synchronize Virtual Tape configurations is to enable Hot Spares or the auto rebuild feature. Connect to Diamond Storage Array services via the RS-232 port or the optional Ethernet management services card (see Diamond-VT on page 15).
  • Page 78: Hardware Maintenance

    ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual Exhibit 10-1: The management card may be accessed via a serial port DB-9 connector or an optional Ethernet connection.
  • Page 79 Exhibit 10-2: Above, disk drive sled partially pulled out of the Diamond Storage Array. Bottom left, top of disk drive sled. Bottom right, underside of disk drive sled showing individual drives Exhibit 10-4: A power supply pulled out from a rackmount Diamond Storage Array: do not leave an empty opening while the Diamond Storage Array is operating.
  • Page 80: Disk Drives

    1 disk drive sled. ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual The Drive Sled Number identified in step 2 is the SledNum variable to be entered into the CLI commands.
  • Page 81 Power Supplies CAUTION CAUTION Do not leave empty openings on the front or rear of the Diamond-VT under any circumstances. Empty openings affect airflow and may cause the unit to overheat and shut down. WARNING Hazardous voltage and stored energy hazard when removing power supplies.
  • Page 82: Appendix A Glossary

    A FC switch or two or more FC switches interconnected to physically transmit data between any two N_Ports on a switch or switches ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual ; the Fibre Channel Consortium www.iol.unh.edu/consortiums/index.html a range of up to 10 kilometers running at speeds of 1 gigabit/sec.
  • Page 83 Term F_port A port in the FC fabric where a N_port may attach FC-AL Fibre Channel Arbitrated Loop: an FC network in which up to 126 systems and devices are connected in a loop topology, with each transmitter connecting to the receiver of the device to its logical right;...
  • Page 84 • Drives Manageability A-iii ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual ATA disk drives are used in the enormous PC marketplace and an estimated 85% of all disk drives sold today contain an ATA interface. Shipments of...
  • Page 85 Appendix C Information Command Returns Driveinfo Sled Capacity Errors TYPE VDID === ====== ===== ===== ===== 1 76292MB 0 JBOD 1 2 76292MB 0 JBOD 2 3 76292MB 0 JBOD 3 4 76292MB 0 JBOD 4 5 76292MB 0 JBOD 5 6 76292MB 0 JBOD 6 7 76292MB...
  • Page 86 RAID10 ONLINE 293231MB LunInfo 2 RAID10 SerialNumber V80EE4TCAAL0000 Virtual Drive ID 57, Capacity: 305171 MB (0x00025409e00 blocks) Operations Blocks Read 00000000 00000000 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual Errors SerialNumber V80EE4YCXAI0000 V80EE4HCXAI0000 V80DTESCXAI0000 V80DTCWCXAI0000 V80EE4TCXAI0000 V80CG4RCXAI0000...
  • Page 87 Write 00000000 00000000 Errors 00000000 LunInfo for a RAID5 1 configuration TYPE State Capacity ==== ===== ====== Processor ONLINE RAID5 ONLINE 1612749MB LunInfo 1 RAID5 SerialNumber V80EE4YC5AM0000 Virtual Drive ID 59, Capacity: 1612749 MB (0x000c4de6f00 blocks) Operations Blocks Read 00000000 00000000 Write 00000000 00000000 Errors 00000000 LunInfo for a RAID5 4 configuration...
  • Page 88 Device: 3 4 5 6 ZoneInfo 1 Zone: zone1 enabled Host: 20:00:00:10:00:00:00 IID: none Port: 1 Device: 12345 A-vii ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual Used Protection disabled Serial Number ========= Serial Number = ... ========== Serial Number = ...
  • Page 89 A-viii...
  • Page 90 Copies what is in the Planned Zoning Configuration to the Active Configuration: in this case, clears any previously-defined zones. A-ix ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual ZoneCommit affect only the planned configuration. ZoneCommit sets the Planned Configuration into the Active Configuration.
  • Page 91 Asymmetric Model 3 hosts, 1 metadata controller (also a host), RAID 5 with 3 LUNs. All zone commands except ZoneCommit affect only the planned configuration. ZoneCommit ZoneClearAll ZoneCreate zone_1 ZoneAddHost zone_1 20:00:00:10:86:00:01:34 ZoneAddHost zone_1 20:00:00:10:10:10:86:01 ZoneAddDevice zone_1 1 2 ZoneAddPort zone_1 0 ZoneCreate zone_2 ZoneAddHost zone_2 20:00:00:60:32:01:02:12 ZoneAddHost zone_2 20:00:00:10:10:10:86:01...
  • Page 92 ZoneAddPort zone_2 1 ZoneState zone_1 enabled ZoneState zone_2 enabled ZoneCommit A-xi ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual sets the Planned Configuration into the Active Configuration. Clears any previously defined zones Creates a zone named zone_1 Adds host 1 WWPN to zone_1...
  • Page 93: Appendix E Specifications

    Appendix E Specifications Environmental and physical • Humidity: 10-85% non-condensing • Normal operating temperature at sea level: 5- • Storage temperature: -25-60 • AC input voltage 100-240V rated • 50/60 Hz Rack Mount Dimensions • Height: 131mm (5.16”) 3U • Width: 447mm (17.60”) •...
  • Page 94 A-xiii ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual • This unit is designed to only have inside communication lines connected to it (no lines outside the building proper).
  • Page 95 Appendix G Part numbers Each Diamond-VT has a master part number to identify it. The floor model base number is on the side of the unit. The rack mount part number is on the top of the unit and near the host interface cards. System management card (Ethernet) System management card (RS-232) *Cable, 3 meter copper FC (unequalized) (1 Gb FC)
  • Page 96 Amherst, New York 14068 (716) 691-1999 • voice (716) 691-9353 • fax http://www.attotech.com/diamond ATTO Technology can also be reached via e-mail at the following addresses: Sales Support: Technical Support: A-xv ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual Manufacturer’s product(s) will be the customer’s...

This manual is also suitable for:

Diamond array vt

Table of Contents