ATTO Technology Diamond Storage Array VT-Class Installation And Operation Manual page 33

Diamond storage array
Table of Contents

Advertisement

8
Call technical support (see
Appendix, page xv) to get the appropriate MIB
file for your Diamond-VT.
9
For each client, copy the MIB file to the
directory containing the SNMP management
software.
10 From within the SNMP management software,
compile the file attodmnd-mib.mib according
to the software's procedures.
11 Unload any default MIBs.
12 Load the Diamond MIB ATTODIAMOND.
13 When requested, enter the Diamond-VT IP
address as the Remote SNMP Agent.
Warranty
in the
14 The SNMP management software contacts the
agent in the Diamond-VT. The screen displays
system information.
15 Status is monitored and reported through the
SNMP management software.
Traps are generated for the following situations:
• Temperature status changes in any of the
sensors located on the Diamond-VT mid-plane.
• A drive or a sled is physically removed from the
Array or put into the Array.
• The power supply is turned on or off.
• The fan is physically stopped.