Resetting the Diamond-VT to defaults will not alter the RAID configuration, zoning configuration, IP
configuration or Telnet information. However, resetting the Diamond-VT to factory defaults is a last-ditch effort
to recover from corrupt configurations or complete failure. All data will be lost, but the zoning configuration will
remain.
CAUTION
CAUTION
Data will be lost if you follow these
procedures. Make sure you have no other
choice before resetting the Diamond-VT to
factory defaults.
Default
If you need to return to the default settings of the
Diamond-VT but do not want to lose data or Ethernet
settings, use the CLI command
in CLI mode or in the Advanced CLI
default
configuration page of the ExpressNAV interface.
Note
RestoreConfiguration default or
Using
RestoreConfiguration factory default will not
affect the zoning configuration. To restore the
Diamond-VT to factory default, type
ZoneClearAll
ZoneCommit
Return to Default settings
1
Connect to Diamond-VT services via the RS-232
port or the optional Ethernet management
Accessing the Diamond-VT
services card (see
page 15). You should now be in Command Line
Interface. Continue with the CLI or access the
ExpressNAV interface (see
Browser-based Interface
Note
Because the ExpressNAV pages take you
through this process easily, the following
instructions are based on the CLI commands.
Use these instructions as a guide in ExpressNAV.
RestoreConfiguration default
2
Type
system configuration (See Exhibit 9.2-2 for a list of
configurations which will be changed).
FirmwareRestart
3
Type
Diamond-VT.
63
ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual

9.2 Resetting Defaults

RestoreConfiguration
on
ATTO ExpressNAV:
on page 23).
to reset the
or cycle power of the
4
Reboot the host PC after the Diamond-VT
completes its power on cycle.
Factory Default
Resetting the Diamond-VT to factory defaults is a last-
ditch effort to recover from corrupt configurations or
complete failure. All data will be lost.
Note
RestoreConfiguration default or
Using
RestoreConfiguration factory default will not
affect the zoning configuration. To restore the
Diamond-VT to factory default, type
ZoneClearAll
ZoneCommit
To reset to Factory Defaults, firmware version
2.5.3 or higher
1
Connect to Diamond-VT services via the RS-232
port or the optional Ethernet management
Accessing the Diamond-VT
services card (see
page 15). You should now be in Command Line
Interface.
2
Continue with the CLI or access the ExpressNAV
ATTO ExpressNAV: Browser-based
interface (see
Interface
on page 23).
Note
Because the ExpressNAV pages take you
through this process easily, the following
instructions are based on the CLI commands.
Use these instructions as a guide in ExpressNAV.
RestoreConfiguration factorydefault
3
Type
the system configuration. (See Exhibit 9.2-2 for a
list of configurations which will be changed).
FirmwareRestart
4
Type
power.
5
Reboot the host PC after the Diamond-VT
completes its power on cycle.