Nortel FastRad Installation Manual page 26

Nortel networks telephone installation guide
Table of Contents

Advertisement

16
FastRAD Installation Guide
17. Press OK.
The display shows:
18. Press CHNG.
The display shows:
19. Enter the number of minutes between retries. This must be
a number between 1 and 99.
20. Press OK.
The display shows:
21. To change the baud rate, press CHNG until the desired baud
rate appears. The baud rate should match that of the alarm
device's modem. You have three choices: Low, Medium
and High. The default is High.
IMPORTANT: Changing the baud rate is not required un-
less the alarm centre modem is connected to a slow de-
vice, such as an old printer. Selecting the Low setting
limits the baud rate to less than 300. Selecting the Medium
setting limits the baud rate to less than 1200. Selecting the
High setting, the baud rate is determined entirely by the
FastRAD and the alarm centre modems.
22. Press NEXT.
The display shows:
23. To change the parity setting, press CHNG until the desired
setting appears. The parity should match that of the alarm
device's modem. You have three choices: None, Odd and
Even. The default is None.
24. Press NEXT.
The display shows:
Retry mins: 15
BACK
CHNG
NEXT
Retry mins:_
CLEAR
BKSP
Alarm baud: High
BACK
CHNG
NEXT
Parity: None
BACK
CHNG
NEXT
RAD Admin