Data Rate; Interface Options; Safety Agency Certification; Table 65 Interface Options - Nortel 2000 Using Manual

Business policy switch
Hide thumbs Also See for 2000:
Table of Contents

Advertisement

Data rate

The data rate is 10 Mb/s Manchester encoded or 100 Mb/s 4B/5B encoded.

Interface options

Table 65

Table 65 Interface options

Option
10BASE-T/100BASE-TX
100BASE-FX Fiber
1000BASE-SX (Shortwave
Gigabit Fiber) MDA
1000BASE-LX (Longwave
Gigabit Fiber) MDA

Safety agency certification

The safety certifications follow:
UL Listed (UL 1950)
IEC 950/EN60950
C22.2 No. 950 (CUL) with all national deviations
UL-94-V1 flammability requirements for PC board
NOM (NOM-019)
lists interface options.
Description
RJ-45 (8-pin modular) connectors for MDI-X interface
SC and MT-RJ connectors for switched 100 Mb/s
(100BASE-FX) connections over 50/125 and 62.5/125
micron multimode fiber optic cable (2 km/6562 ft maximum
distance)
SC connectors for shortwave 850 nm fiber optic
connections over multimode (550 m/1805 ft) fiber optic
cable
SC connectors for longwave 1300 nm fiber optic
connections over single-mode (3 km/9843 ft) or multimode
(550 meter/1805 ft) fiber optic cable
Appendix A Technical specifications 337
Using the Business Policy Switch 2000 Version 1.2

Advertisement

Table of Contents
loading