Once Connection Scheme; Host I/F Operation; Figure 3-1 Host System Debug Scheme A - Motorola MSC8101 ADS User Manual

Motorola msc8101 ads motorola metrowerks user's manual
Table of Contents

Advertisement

The MSC8101ADS may be configured according to the required working environment as follows:
Host Controlled Operation through OnCE Port
Host Interface Operation through HDI16 Port
Stand-Alone Mode
3•1

OnCE Connection Scheme

In this configuration the MSC8101ADS is controlled by a host computer via the OnCE Port, which
is a subset of the JTAG port. This configuration allows for extensive debugging using on-host de-
bugger. The host is connected to the ADS by a Command Converter provided by a third party
(Macraigor Systems).
Host
Computer
Media I/F
3•2

Host I/F Operation

In this configuration the MSC8101ADS is using HDI16 I/F that provide 16-bit wide, full-duplex,
double-buffered, parallel port to connect directly to the data bus of a host processor. The HDI16
supports two classes of interfaces:
Host processor/Microcontroller (MCU) connection interface
DMA controller interface
A Host Device may be connected to the ADS via dedicated 36pin two rows header or via 128pin
DIN - connector P2.
MOTOROLA
Freescale Semiconductor, Inc.
Installation Instructions
3 - Installation Instructions

FIGURE 3-1 Host System Debug Scheme A

Command
Converter
14 Wire
Flat Cable
5V Power Supply
MSC8101ADS RevB User's Manual
For More Information On This Product,
Go to: www.freescale.com
19