Comtech EF Data SMS-758 Installation And Operation Manual page 142

Modem protection switch
Table of Contents

Advertisement

Remote Control Operation
A–20
Character "w": Missing parameters fault status character 4.
Bit 6 = 1 always.
Bit 5 = No configuration for prime demodulator #7 fault.
Bit 4 = No configuration for prime demodulator #8 fault.
Bit 3 = No configuration for backup demodulator #1 fault.
Bit 2 = No configuration for backup demodulator #2 fault.
Bit 1 = Reserved.
Bit 0 = Reserved.
Character "x": Missing parameters fault status character 5.
Bit 6 = 1 always.
Bit 5 = No address specified for prime modem #1 fault.
Bit 4 = No address specified for prime modem #2 fault.
Bit 3 = No address specified for prime modem #3 fault.
Bit 2 = No address specified for prime modem #4 fault.
Bit 1 = No address specified for prime modem #5 fault.
Bit 0 = No address specified for prime modem #6 fault.
Character "y": Missing parameters fault status character 6.
Bit 6 = 1 always.
Bit 5 = No address specified for prime modem #7 fault.
Bit 4 = No address specified for prime modem #8 fault.
Bit 3 = No address specified for backup modem #1 fault.
Bit 2 = No address specified for backup modem #2 fault.
Bit 1 = Reserved.
Bit 0 = Reserved.
Character "z": Missing parameters fault status character 7.
Bit 6 = 1 always.
Bit 5 = No interface specified for prime modem #1 fault.
Bit 4 = No interface specified for prime modem #2 fault.
Bit 3 = No interface specified for prime modem #3 fault.
Bit 2 = No interface specified for prime modem #4 fault.
Bit 1 = No interface specified for prime modem #5 fault.
Bit 0 = No interface specified for prime modem #6 fault.
Character "aa": Missing parameters fault status character 8.
Bit 6 = 1 always.
Bit 5 = No interface specified for prime modem #7 fault.
Bit 4 = No interface specified for prime modem #8 fault.
Bit 3 = No interface specified for backup modem #1 fault.
Bit 2 = No interface specified for backup modem #2 fault.
Bit 1 = Reserved.
Bit 0 = Reserved.
Character "ab": Missing parameters fault status character 9.
Bit 6 = 1 always.
Bit 5 = No downlink specified for prime modem #1 fault.
Bit 4 = No downlink specified for prime modem #2 fault.
Bit 3 = No downlink specified for prime modem #3 fault.
Bit 2 = No downlink specified for prime modem #4 fault.
Bit 1 = No downlink specified for prime modem #5 fault.
Bit 0 = No downlink specified for prime modem #6 fault.
SMS-758 Modem Protection Switch
MN/SMS758 Rev. 3

Advertisement

Table of Contents
loading