M:n Switch Fault Status Summary; Missing Parameter Faults - Comtech EF Data SMS-758 Installation And Operation Manual

Modem protection switch
Table of Contents

Advertisement

SMS-758 Modem Protection Switch
A.3.5.7.3 M:N Switch Fault Status Summary
Command:
Response:
Note: Fault status data is only returned if fault conditions exist.
A.3.5.7.4 Missing Parameter Faults
Command:
Response:
Note: Fault status data is only returned if fault conditions exist.
MN/SMS758 Rev. 3
<add/MNF_"cr"
>add/MNF_"cr"
COM_FLT_xxxxxxxxByBy"cr"
MOD_CONFIG_FLT_xxxxxxxxByBy"cr"
DMD_CONFIG_FLT_xxxxxxxxByBy"cr"
MOD_COMPAT_FLT_xxxxxxxxByBy"cr"
DMD_COMPAT_FLT_xxxxxxxxByBy"cr"
+12V_FLT"cr"
-12V_FLT"cr"
+5V_FLT"cr"
PS1_FLT"cr"
PS2_FLT"cr"
M&C_BAT_FLT"cr"
ADX_BAT_FLT"cr"
PARAMETER(S)_MISSING"cr""lf"]
Where:
x = 1 to 8 (prime modem number).
y = 1 or 2 (backup modem number).
<add/MPF_"cr"
>add/MPF_"cr"
NO_MOD_CONFIG_xxxxxxxxByBy"cr"
NO_DMD_CONFIG_xxxxxxxxByBy"cr"
NO_ADX_xxxxxxxxByBy"cr"
NO_INTFC_xxxxxxxxByBy"cr"
NO_DL_xxxxxxxx"cr""lf"]
Where:
x = 1 to 8 (prime modem number).
y = 1 or 2 (backup modem number).
Remote Control Operation
Modem communications faults
Mod configuration verify faults
Demod configuration verify faults
(see Note)
Mod compatibility fault
(see Note)
Demod compatibility fault
(see Note)
Power fault +12V
(see Note)
Power fault -12V
(see Note)
Power fault +5V
(see Note)
Powers supply #1 fault
(see Note)
Power supply #2 fault
(see Note)
M&C battery fault
(see Note)
Address Decoder/Driver battery fault
(see Note)
Missing parameter fault, use "MPF"
command to determine faults
No mod configuration loaded
No demod configuration loaded
No address specified for modem
No interface specified for modem
(see Note)
No downlink specified for demod
Note)
(see Note)
(see Note)
(see Note)
(see Note)
(see Note)
(see Note)
(see