Important Information - Dean D50 Installation, Operation & Maintenance Manual

Decathlon series gas fryers (ce)

Advertisement

2. IMPORTANT INFORMATION

2.1 DESCRIPTION:
Fat Decathlon Fryers are energy-efficient,
gas-fired units, design-certified by the
International
(AGA/CGA),
International and manufactured to their
basic
performance
specifications.
All
units
are
assembled with accessories packed inside
the fryer vessel. All units are adjusted,
tested and inspected at the factory before
shipment. Sizes, weights and input rates
of all models are listed in this manual.
NOTE:
The on-site supervisor is responsible
for ensuring that operators are made
aware
of
operating a deep fat fryer, particularly
aspects of oil filtration, draining, and
cleaning of the fryer.
2.2 PRINCIPLE OF OPERATION:
The incoming gas flows through orifices
and is mixed with air in the burners to
create
the
correct
combustion. The mixture is ignited at the
front end of each heat tube by the pilot
light.
As the flame goes through the
burner tube, it is slowed by internal
diffusers. This slower and more turbulent
flame gives much better heat transfer to
the walls of the tubes, thereby heating the
oil better.
2.3 RATING PLATE:
the inside right-hand corner of the front
door panel. Information provided includes
the model and serial number of the fryer,
BTU/hr input of the burners, outlet gas
pressure in inches WC and whether the
unit has natural or propane gas orifices.
The Dean CE Deep
Approval
Services
Gaz
de
France,
and
application
shipped
completely
inherent
dangers
ratio
for
proper
This is attached to
THE FRYER MUST BE CONNECTED
ONLY TO THE TYPE OF GAS IDENTIFIED
NSF
ON THE ATTACHED RATING PLATE.
2.4 PRE-INSTALLATION:
a. GENERAL: Only a licensed plumber
should install any gas-fired equipment.
1. A manual gas shut-off valve must
2. The Dean CE Decathlon gas fryers
of
Local building codes usually prohibit a fryer
with its open tank of hot oil from being installed
beside an open flame of any type, whether a
broiler or the open burner of a range.
b. CLEARANCES: The fryer area must
be
combustibles.
certified
installations:
1. Other than household use;
2. Non-combustible floor installation
3. Combustible construction with a
3
DANGER!
be installed in the gas supply line
ahead of the fryer(s) for safety and
ease of future service.
require 230 volts (AC) 50 cycle
electrical service and are equipped
with a 16-3 SJT grounded flexible
power cord for a direct connection
to the power supply.
draw for each unit depends on the
accessories supplied with the unit.
See detailed instructions packaged
with the fryer line-up.
CAUTION
kept
free
and
clear
This unit is design-
for
the
equipped with factory-supplied 15
cm adjustable legs or 13 cm
casters;
minimum clearance of 15 cm side
Amperage
of
all
following

Advertisement

loading

This manual is also suitable for:

D60