i. Re-install filter support grid. Place
two sheets of filter paper on top of the
support grid. Push paper to the filter
pan bottom with the hold-down ring.
Latch the hold-down ring into place.
j. Then reinstall the crumb catcher (if
provided) inside the filter pan. Place
the filter cover on top of filter pan and
slide the filter back inside the fryer.
k. Reconnect oil return quick disconnect
lines (if installed on the fryer).

6.3 FILTER OPERATION:

Dean Filter Systems are designed to be
used as either a portable unit or a built-in
filter as part of a fryer/filter system.
Portable means that it can be moved from
fryer to fryer.
The primary difference between filter
systems is how the filtered oil is returned
to the fryer vessel. Built-in systems have
an internally-plumbed oil return line
running from the filter' s quick disconnect
to a special port in the fryer vessel' s rear
wall where oil re-enters the fryer vessel.
Portable systems return the filtered oil by
means of a flexible oil return hose which
connects to the filter' s quick disconnect.
The operator uses a wand connected to
the end of the flexible oil return hose to
direct filtered oil into the fryer vessel
from above.
Filter operations always start with making
sure the unit is properly plugged in, then
rolling the filter to the fryer to be filtered.
The filter works directly under the fryer's
drain valve.
a. Portable Filter Operation:
1. Open the drain valve by pulling
the handle out.
transfer from the fryer vessel to
the filter pan.
Drain Valve
with
Extension
The oil will
17
Arrows show
direction of oil
flow.
Fryer Vessel
Portable Filtration System
FIGURE 6-2
2. Turn the filter switch to the "ON"
position on the filter control panel
to begin pumping oil into fryer. If
your filter unit is equipped with a
flexible
nozzle is positioned to return oil
safely into the fryer vessel.
3.
When oil and fryer vessel are
clean, close the drain valve.
takes the filter approximately 5 to
7 minutes to pump all oil back
into the fryer. Run the filter pump
an additional 10-15 seconds after
bubbles appear in oil to clear oil
return lines.
4.
Make sure the drain valve is fully
closed.
Oil
Return
Hose
Quick
Disconnect
Pump
Filter
hose/nozzle,
ensure
It