INSTALLATION

Safety

INSTALLATION
7.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
7.1

General safety instructions

We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
7.2

Instructions, standards and regulations

Note
Observe all applicable national and regional regulations
and instructions.
8.

Appliance description

8.1

Standard delivery

The following are delivered with the appliance:
- Wall mounting bracket (2 pce for appliances with 120 l and
150 l nominal capacity)
- Spacers 5 mm (2 pce at the top / 2 pce at the bottom; for ap-
pliances with 120 l and 150 l, 4 pce at the top / 4 pce at the
bottom)
- Caps (2 pce)
- Installation template
8.2

Accessories

Required accessories
Various safety assemblies are available for sealed unvented (pres-
sure-tested) operation, depending on the static pressure. These
type-tested safety assemblies protect the appliance against im-
permissible excess pressure.
Further accessories
Taps are available as accessories for open vented operation.
www.stiebel-eltron.com
9.

Preparations

9.1

Installation site

The appliance is designed for installation on a solid wall. Ensure
the wall offers adequate load bearing capacity.
Always install the appliance vertically in a room free from the risk
of frost and near the draw-off point.
9.2

Fitting the wall mounting bracket

f You can use the installation template to transfer the dimen-
f
sions to the wall.
f Drill the holes and secure the wall mounting bracket with
f
screws and rawl plugs. Select fixing materials in accordance
with the wall construction/condition.
You can compensate for unevenness in the wall with the spacers
provided.
Appliances with a nominal capacity of 120 l or 150 l require 2 wall
mounting brackets.
1
2
1 Upper spacer
2 Lower spacer
9.3

Preparing the connecting cables

120
270
SH S |
23