    cOntents OperatiOn��������������������������������������������� 6 1. General information ��������������������������������������������6 1.1 Document information �������������������������������������������� 6 1.2 Key to symbols ������������������������������������������������������ 6 2. Operating instructions �����������������������������������������6 2.1 Description of unit � ������������������������������������������������� 6 2.2 The most important points in brief ������������������������� 7 2.3 Operation ������������������������������������������������������������ 7 2.4 Safety information ������������������������������������������������� 7 2.5 Important notes � ���������������������������������������������������� 7 installatiOn������������������������������������������ 8 3. Safety ������������������������������������������������������������8 3.1 General safety instructions ��������������������������������������� 8 3.2 Instructions, standards and regulations �����������������������...
  • Page 3 1,0 kW 2,0 kW 3,0 kW 4,0 kW 30 l 60 l 90 l 120 l 150 l 50 ° C 12 h 11 h 1,0 kW 10 h 2,0 kW 3,0 kW 4,0 kW 30 l 60 l 90 l 120 l 150 l 70 ° C 40°C sH 3 0s(gB) 10l...
  • Page 4 G 12.7 (½") 12 * < 500 |sH s (gB) www.stieBel-eltrOn.cOm...
  • Page 5 SH 30 S (GB), SH 50 S (GB), SH 150 S (GB) 260 mm 380 mm SH 80 S (GB), SH 100 S (GB), SH 120 S (GB) 240 mm 350 mm www.stieBel-eltrOn.cOm sH s (gB)|...
  • Page 6: Operation

    OperatiOn general infOrmatiOn 1. General information 2. Operating instructions 1.1 documentinformation 2.1 descriptionofunit The chapter Operationis intended for the equipment user and the SH 30 - 150 S (GB) wall-mounted water heaters are intended for heating contractor. heating cold water. To suit requirements, they can provide hot water up to about 70 °C and can supply one or more draw-off The chapter installation is intended for contractors. points depending on the operating mode. The water is heated electrically in single-circuit operation. Automatic reheating to the Please read! preset temperature takes place automatically. The water volume Read these instructions carefully before using the ap- available in each situation is indicated by lights (LED’s) on the pliance and retain them for future reference. If the control panel. The wall-mounted water heater is provided with appliance is passed on to a third party please hand corrosion protection by means of an incorporated signal anode. these instructions to the new user. The unvented (pressurized) wall-mounted water heater can be for 1.2 Keytosymbols the supply of several draw-off points. symbolsintheseinstallationinstructions: Infinite temperature adjustment is possible from about 35 °C to In this documentation you will come across symbols and high- about 70 °C (1). lights. These have the following meaning: The heating-up process is indicated by the signal lamp (2). Risk of injury! The time required for heating up is dependent on the storage content, the cold water temperature, and the heating capacity,...
  • Page 7: The Most Important Points In Brief

    OperatiOn Operating instrUctiOns 2.2 themostimportantpointsinbrief 1 Temperature selection button 2 Signal lamp for operating mode 3 Lights for the heat content display 4 „SERVICE ANODE“ signal lamp 2.3 Operation Temperature selection button (1) • = cold (see also Instructions, Risk of Freezing) E = (approx. 60 °C) Recommended energy economy setting, low limescale formation 70 °C = Maximum temperature which can be set. Depending on the system, the temperatures may deviate from the reference value. 2.4 safetyinformation Risk of scalding! There is a risk of scalding at outlet temperatures in excess of 43 °C. Risk of injury! Where children or persons with limited physical, sen- sory or mental capabilities are to be allowed to control this appliance, ensure that this will only happen under supervision or after appropriate instructions by a per- son responsible for their safety. Children must be supervised to ensure that they do not play with the appliance.
  • Page 8: Installation

    installatiOn safety 3. Safety 3.4 electricalinstallation Only qualified contractors should carry out installation, commis- Electrical connection only with fixed-laid leads in sioning, maintenance and repair of the appliance. association with removable cable bushings. 3.1 generalsafetyinstructions The unit must be capable of all-pole disconnection We guarantee trouble-free function and operational reliability from the mains, for example by fuses, with an isola- only if the original accessories and spare parts intended for the ting distance of at least 3 mm. appliance are used. 3.5 Operatingandinstallationinstructions 3.2 instructions,standardsandregulations Keep these Instructions carefully. In the event of a change of ow- Observe all applicable national and regional regulati- nership, hand them over to the new owners, and give them to the ons and instructions. qualified installer to read in the event of maintenance and possible repair work being carried out. The installation of the system is subject to approval under the Building Regulations, Water Byelaws and 4. Equipment description Regulations, the Health and Safety at Work Act 1974 (where appropriate) and the Health and Safety at Work The system is designed to operate with mains water pressure, and (Northern Ireland) Order 1978 (where appropriate). a set of fittings is provided for this purpose. 5. Installation instructions 3.3 waterinstallation 3.3.1 Cold water line Delivered with the appliance are: Steel or copper pipes or plastic pipework are approved as mate-...
  • Page 9: Structure Of The Device

    installatiOn installatiOn instrUctiOns 5.1 structureofthedevice See chapter „Specification / Hydraulic diagram“ for general ar- rangement in schematic form. You can fit the safety assembly in various positions to suit the space available but it must be placed 1 Heating element in the same order as shown. The safety assembly provided in the 2 Service anode pack is fitted to the cold water supply with the exception of the – SH 30 S (GB)- M 8: Replace with heating element fitting T&P valve which is fitted at the top of the DHW cylinder. – SH 50 - 150 S (GB) - G 19.05 (¾"): Replace without heating To obtain a balanced water pressure in the cold water and DHW » element fitting lines, position the cold water outlet directly on the outlet side of 3 Pressure switch for service anode the pressure relief valve. 4 Combined thermostat and high-temperature cut-out 4a High temperature cut-out reset button (accessible from The T&P valve should not respond under normal operating con- » the front) ditions as the expansion vessel will accommodate the water as 5 Electronic stored heat display it expands during the heating process. 6 Heating element flange Check the pre-charge pressure of the expansion vessel and, » 7 Gasket where appropriate, regulate it to 0.35 MPa.
  • Page 10: Electrical Connection

    installatiOn installatiOn instrUctiOns 5.4 electricalconnection 5.8 maintenance Remove the bottom cap from the device by drawing off the re- When carrying out any work, disconnect all poles from the mains » » gulator button and removing the screws supply. Electrical connection lead Check the safety group regularly. » » 5.4.1 Electrical circuit diagram Descale the element only after dismantling. Do not treat the » reservoir surface and parasitic current anode with descaling 1 Thermostat agents. 2 Safety temperature limiter safetydevice 3 Pressure switch for signal anode 4 Heat content display Regulator-limiter combination immersion depths » 5 Plug distributor for N-lead a - Limiter sensor 6 Terminal for power switchover b - Regulator sensor 5.4.2 Connection variant drainingthestoragewaterheatercylinder Before draining the cylinder, disconnect the unit from the mains...
  • Page 11: Specification

    installatiOn | gUarantee | enVirOnment and recycling installatiOn instrUctiOns 5.9 specification model sealed UnVented wall mounted dHw cylinder Type SH 30 S (GB) SH 50 S (GB) SH 80 S (GB) SH 100 S (GB) SH 120 S (GB) SH 150 S (GB) Part number 228948 228949 228950 228951 228952 228953 Operating details Rated output 1, 2, 3, 4 1, 2, 3, 4 1, 2, 3, 4 1, 2, 3, 4 1, 2, 3, 4 1, 2, 3, 4 Connectable to power 1/N/PE...
  • Page 12 Deutschland Verkauf* Tel. 0180 3 700705 | Fax 0180 3 702015 | info-center@stiebel-eltron.de STIEBEL ELTRON GmbH & Co. KG Kundendienst* Tel. 0180 3 702020 | Fax 0180 3 702025 | kundendienst@stiebel-eltron.de Ersatzteilverkauf* Tel. 0180 3 702030 | Fax 0180 3 702035 | ersatzteile@stiebel-eltron.de Dr.-Stiebel-Straße | D-37603 Holzminden...