INSTALLATION

Settings

12. Settings
Limiting the temperature selection
You can adjust the temperature selection limit beneath the tem-
perature selector.
f Set the temperature selector to "cold" and isolate the appli-
f
ance from the power supply.
f Remove the temperature selector.
f
3
2
1 Temperature selector
2 Temperature selection limit at 45 °C, 55 °C, 65 °C
3 Factory setting 85 °C
f Adjust the temperature selection limit.
f
f Replace the temperature selector.
f

13. Shutting down

f Disconnect the appliance from the mains at the MCB/fuse in
f
the fuse box.
f Drain the appliance (see chapter "Maintenance / Draining the
f
appliance").
26
| SH S

14. Troubleshooting

Note
At temperatures below –15 °C the high limit safety cut-out
may respond. The appliance may be subjected to these
temperatures during storage or transport.
Fault
The water does not heat
up.
1
The safety valve drips
when heating is switched
off.
SERVICE ANODE indicator
illuminates.
Reset key, high limit safety cut-out
The reset button is located behind the temperature selector.
f Pull off the temperature selector.
f
1 Reset key, high limit safety cut-out
2 Controller/limiter combination
Cause
Remedy
The high limit safety
Remedy the cause of
cut-out has responded
the fault. Replace the
because the controller is
controller-limiter com-
faulty.
bination.
The high limit safety
Press the reset button
cut-out has responded
(see diagram).
because the temperature
has fallen below -15 °C.
The flanged immersion
Replace the flanged im-
heater is faulty.
mersion heater.
The valve seat is contam-
Clean the valve seat.
inated.
The signal anode has
Replace the signal anode.
been consumed.