Yamaha FJR1300A(D) Service Manual page 640

Table of Contents

Advertisement

Air temperature sensor resis-
tance
5.4–6.6 kΩ at 0 °C (32.0 °F)
290–390 Ω at 80.0 °C (176.0 °F)
▼▼▼
▼ ▼▼▼
▼ ▼▼▼
a. Connect the pocket tester (Ω × 100/× 1 kΩ) to
the air temperature sensor terminals as
shown.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
b. Immerse the air temperature sensor "1" in a
container filled with water "2".
TIP
Make sure that the air temperature sensor termi-
nals do not get wet.
c. Place a thermometer "3" in the water.
3
d. Heat the water or let it cool down to the spec-
ified temperatures.
e. Measure the air temperature sensor resis-
tance.
▲▲▲
▲ ▲▲▲
▲ ▲▲▲
EAS1MC1026
CHECKING THE GEAR POSITION SWITCH
1. Remove:
• Gear position switch
(from crankcase)
2. Check:
• Gear position switch
Out of specification → Replace the gear posi-
tion switch.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
▼ ▼▼▼
▼ ▼▼▼
▼ ▼▼▼
1
2
▲ ▲▲▲
▲ ▲▲▲
▲ ▲▲▲
ELECTRICAL COMPONENTS
Result
▼▼▼
▲▲▲
f
b
a
EAS1MC1027
CHECKING THE FUEL INJECTORS
1. Check:
• Fuel injector resistance
Out of specification → Replace the fuel injec-
tor.
8-191
Neutral position
Continuity
Positive tester probe →
sky blue "1"
Negative tester probe →
Switch terminal "a"
1st position
Continuity
Positive tester probe →
black/yellow "2"
Negative tester probe →
Switch terminal "b"
2nd position
Continuity
Positive tester probe →
pink "3"
Negative tester probe →
Switch terminal "c"
3rd position
Continuity
Positive tester probe →
yellow/white "4"
Negative tester probe →
Switch terminal "d"
4th position
Continuity
Positive tester probe →
blue/white "5"
Negative tester probe →
Switch terminal "e"
5th position
Continuity
Positive tester probe →
black/red "6"
Negative tester probe →
Switch terminal "f"
e
3
5
P
L/W B/R
Sb
d
1
c
4
Y/W
6
B/Y
2