Adam Equipment WSK 8 User Manual page 24

Warrior series
Hide thumbs Also See for WSK 8:
Table of Contents

Advertisement

This group of parameters is used to control the operation of the scale.
Parameter
S1 Un
S2 bL
S3 AoF
S4 dt
S5 diS
S6 Fi
S7 SPS
S8 CAL
Description
Enable or disable
weighing units, will not
allow to disable all
units, at least one has
to be enabled. Parts
counting can be
enabled/disabled
Backlight set to
always on, always off
or automatic on
whenever a weight is
placed or a key is
pressed
Auto Off- Disable or
set time increment to
turn off scale
Set Time and Date
format and settings.
Format for date can
be changed when the
display shows
mmddyy, ddmmyy or
yymmdd by pressing
the [Pcs/ ] key, then
enter the date.
Display all weights or
only when stable
Filter setting to slow,
normal or fast
Password
Calibration
Page 22
Options
Kg
Grams
lb
oz
lb:oz
N (Newtons)
PCS
EL oFF
EL on
EL AU
SLP 0
SLP 1
SLP 5
SLP 10
Enter the time
manually.
Enter the date
format and then
the numeric value
manually.
ALL, StAb
Slow, nor, FASt
Enter new pass
word twice.
Controls access
to Func 1 to Func
4
Calibrate the
scale. See
Section 11.0
Default
setting
Kg
EL AU
SLP 0
00:00:00
mm:dd:yy
ALL
nor
Not active
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents