3.2
FIXING THE INFRARED SENSOR IN POSITION
a)
The infrared sensor is supplied from the factory attached to a self
adhesive pad. This pad can therefore be attached to the hearth in
a position to suit the form of the bezel that is supplied with the product
Fig. 7 below shows the self adhesive pad and infrared eye attached to
the flying lead, as supplied from the factory.
Fig. 7
Infrared Eye Sensor
b)
Remove the backing paper from the self adhesive pad and position the
infrared eye in the corner of the ashpan cover, so that the infrared
eye is flush with the front edge of the front bezel cover, as shown below
in Fig. 8. Check the operation of the handset, as detailed in Section 3.3
and adjust the position of the infrared eye if necessary.
Fig. 8