Maintenance; Scheduled Maintenance Chart; Engine Oil; Engine Oil Requirements - Champion 100136 Operator's Manual

Home standby generator 12.5 kw
Table of Contents

Advertisement

Before performing maintenance procedures, review SAFETY
section starting on page 7.
Ensure that the ATS and Engine Switches are in the OFF position
before performing any maintenance or cleaning.
SCHEDULED MAINTENANCE
CHART
First
5 Hours of
Operation
Change engine
oil
Change the
√****
engine oil filter
Check engine oil
level
Inspect fuel lines
and connections
Check exterior
fault code
indicator light
Inspect and
clean enclosure
louvers
Inspect and
clean battery
terminals
Inspect and
clean engine air
cleaner
Inspect engine
spark plug
Complete
inspection of
generator and
engine tune-up
* Monthly or 24 hours of continuous operation
** Service sooner if operating in high ambient temperatures or a
dusty and dirty environment.
*** Maintenance should be performed by your service dealer.
**** If so equiped
© 2015 Champion Power Equipment
Every
2 Years
Weekly Monthly
or 100
Hours of
Operation
√**
√****
√*
√**
√***

MAINTENANCE

ENGINE OIL

ENGINE OIL REQUIREMENTS

Use American Petroleum Institute (API) Service Class SN or
better. Do not use special additives. All temperatures full
synthetic 5W-30.

CHECKING THE ENGINE OIL LEVEL

Check the oil level daily when the generator is running for an
extended period of time.
1.
If the generator is running during a utility outage, turn off
all household loads.
2.
Turn the engine control module switch to the OFF position.
3.
Remove the dipstick. Wipe it dry with a clean cloth and
completely reinsert it into the dipstick tube. See figure 12,
page 24.
Figure 11
Model 100136
Part No. 101306 Rev. A
23