READ AND SAVE THIS MANUAL. This manual contains important safety precautions which should be read and understood before operating the product.
Failure to do so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice.
This product is rated in accordance with PGMA (Portable Generator Manufacturers' Association) standard PGMA G300 (Standard for Testing and Validating
Performance of Portable Generators).
Made in China - REV 20180202
REGISTER YOUR PRODUCT ONLINE
at championpowerequipment.com
OPERATOR'S MANUAL
2000W PORTABLE
INVERTER GENERATOR
or visit championpowerequipment.com
Champion Power Equipment, Inc., Santa Fe Springs, CA USA
Page 1
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice. This product is rated in accordance with PGMA (Portable Generator Manufacturers’ Association) standard PGMA G300 (Standard for Testing and Validating Performance of Portable Generators). Made in China - REV 20180202 Champion Power Equipment, Inc., Santa Fe Springs, CA USA...
Page 2
TABLE Of CONTENTS 100306 - 2000W PORTABLE INVERTER GENERATOR TABLE Of CONTENTS Storage ........... . .
100306 - 2000W PORTABLE INVERTER GENERATOR INTRODUCTION SAfETY DEfINITIONS Congratulations on your purchase of a Champion Power The purpose of safety symbols is to attract your attention to Equipment (CPE) product. CPE designs, builds, and supports possible dangers. The safety symbols, and their explanations, all of our products to strict specifications and guidelines.
Using a generator indoors CAN KILL YOU IN MINUTES. DO NOT use electrical cords that are worn, damaged or Generator exhaust contains carbon monoxide. This is a frayed. Use Champion electrical cords only for proper poison you cannot see or smell. application.
Page 5
IMPORTANT SAfETY INSTRUCTIONS 100306 - 2000W PORTABLE INVERTER GENERATOR WARNING CAUTION Running engines produce heat. Severe burns can occur on Improper treatment or use of the generator can damage it, contact. Combustible material can catch fire on contact.
IMPORTANT SAfETY INSTRUCTIONS 100306 - 2000W PORTABLE INVERTER GENERATOR fuel Safety When operating the generator: DO NOT move or tip the generator during operation. DANGER DO NOT tip the generator or allow fuel or oil to spill. GASOLINE AND GASOLINE VAPORS) ARE HIGHLY When transporting or servicing the generator: FLAMMABLE AND EXPLOSIVE.
IMPORTANT SAfETY INSTRUCTIONS 100306 - 2000W PORTABLE INVERTER GENERATOR Safety Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
IMPORTANT SAfETY INSTRUCTIONS 100306 - 2000W PORTABLE INVERTER GENERATOR Operation Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
50% process magenta 1161-L-SF-A This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
CONTROLS AND fEATURES 100306 - 2000W PORTABLE INVERTER GENERATOR CONTROLS AND fEATURES Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Generator 1. Carrying Handle – Used to lift or carry the unit.
CONTROLS AND fEATURES 100306 - 2000W PORTABLE INVERTER GENERATOR Power Panel 1. Power Output – Percentage of available power from 6. AC Overload Reset Button – Used to re-energize generator being used. receptacles after overload fault and reset maintenance schedule.
CONTROLS AND fEATURES 100306 - 2000W PORTABLE INVERTER GENERATOR Outlet Panel 1. Ground Terminal – Consult an electrician for local RECEPTACLES grounding regulations. 12V DC, 8 Amp (Automotive) 2. Circuit Breakers (Push Reset) – Protects the generator May be used to supply electrical power for against electrical overloads.
CONTROLS AND fEATURES 100306 - 2000W PORTABLE INVERTER GENERATOR fCC Statement Parts Included Accessories 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: Oil Funnel ................1 1a. This device may not cause harmful interference.
ASSEMBLY 100306 - 2000W PORTABLE INVERTER GENERATOR ASSEMBLY This unit ships from our factory without oil. It must be properly serviced with fuel and oil before operation. If you have any questions regarding the assembly of your generator, call our Technical Support Team at 1-877-338-0999.
ASSEMBLY 100306 - 2000W PORTABLE INVERTER GENERATOR NOTICE CAUTION The first 5 hours of run time are the break-in period for the Use regular unleaded gasoline with a minimum octane unit. During the break in period stay at or below 50% of the...
OPERATION 100306 - 2000W PORTABLE INVERTER GENERATOR Grounding WARNING Your generator must be properly connected to an appropriate Do not operate or store the generator in rain, snow, or wet ground to help prevent electric shock. weather. WARNING ...
OPERATION 100306 - 2000W PORTABLE INVERTER GENERATOR Starting the Engine NOTICE 1. Make certain the generator is on a flat, level surface. Keep EZ Start dial in “CHOKE” position for only 1 pull of 2. Disconnect all electrical loads from the generator. Never the recoil starter.
OPERATION 100306 - 2000W PORTABLE INVERTER GENERATOR 5. Plug in and turn on the next item. WARNING 6. Allow the engine to stabilize. Connecting a generator to your electric utility company’s 7. Repeat steps 5-6 for each additional item.
Parallel Operation The Champion model 100306 is parallel ready and can be operated in parallel with another Champion unit to increase the total available electrical power. A Champion model 100468 parallel kit (optional equipment) is required for parallel operation.
MAINTENANCE 100306 - 2000W PORTABLE INVERTER GENERATOR MAINTENANCE Changing the Engine Oil Change oil when the engine is warm. Refer to the oil Make certain that the generator is kept clean and stored specification to select the proper grade for your operating properly.
MAINTENANCE 100306 - 2000W PORTABLE INVERTER GENERATOR Cleaning the Spark Arrestor 4. Inspect the electrode on the plug. It must be clean and not worn to produce the spark required for ignition. 1. Allow the engine to cool completely before servicing the 5.
STORAGE 100306 - 2000W PORTABLE INVERTER GENERATOR STORAGE Adjusting the Governor WARNING DANGER Tampering with the factory set governor will void your Gasoline and gasoline vapors are highly flammable and warranty. extremely explosive. Fire or explosion can cause severe burns or death. Only The air-fuel mixture is not adjustable.
STORAGE 100306 - 2000W PORTABLE INVERTER GENERATOR Long Term Storage (more than 1 year) 5. Check engine oil level and add clean, fresh oil if needed. Oil Specifications for proper oil type. For storage over 1 year, the gasoline tank and carburetor must 6.
SPECIfICATIONS 100306 - 2000W PORTABLE INVERTER GENERATOR SPECIfICATIONS fuel Specifications Use regular unleaded gasoline with a minimum octane rating of Generator Specifications 85 and an ethanol content of 10% or less by volume. DO NOT USE E15 or E85. DO NOT OVERFILL.
TROUBLESHOOTING 100306 - 2000W PORTABLE INVERTER GENERATOR TROUBLESHOOTING Problem Cause Solution No fuel. Add fuel. Faulty spark plug. Replace spark plug. Generator will not start. Unit loaded during start up. Remove load from unit. Fill crankcase to the proper level.
Warranty Registration Card and a copy of your sales – Problems caused by parts that are not original Champion Power receipt from one of CPE’s retail locations as proof of purchase. Equipment parts.
Page 34
The United States Environment Protection Agency (U.S. EPA.) and the California Air Resources Board (CARB) Emission Control System Warranty Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and state of California Air Resources Board (CARB) emission regulations.
Page 35
EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1995 and later model year California small off-road engines (SORE) (for other states, 1997 and later model year engines). The ECS Warranty Period shall begin on the date the new engine or equipment is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months thereafter.
Page 36
You must take your CPE engine or the product on which it is installed, along with your warranty registration card or other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is authorized by Champion Power Equipment, Inc. to sell and service that CPE product during his normal business hours.