41

PIPING DIAGRAM

MODELS : WO
Heating cycle direction of flow
Muffler
Dedicated
temperature sensor
compressor for
injection port
mounting
Compressor
Four-way
temperature
sensor
A100LFTA
MODEL : WO
Heating cycle direction of flow
Muffler
Dedicated
temperature sensor
compressor for
injection port
mounting
Compressor
Four-way
temperature
sensor
Sub accumulator
A060LFCA, WOA080LFCA
Discharge
valve
Discharge
valve
- (OU01 - 14) -
Heating emitter
(Floor heating, radiator)
Refrigerant –
water heat exchanger
3-way valve
Muffler
Pressure sensor
Outdoor
temperature sensor
[Outdoor unit]
Heat exchanger
Heating emitter
(Floor heating, radiator)
Refrigerant –
water heat exchanger
3-way valve
Pressure sensor
Outdoor
temperature sensor
[Outdoor unit]
Heat exchanger
Indoor unit
Heat exchange
sensor
2-way valve
Strainer
Expansion
Expansion valve
valve
inlet sensor
Strainer
Heat exchange
inlet sensor
Indoor unit
Heat exchange
sensor
3-way valve
Strainer
Expansion
Expansion valve
valve
inlet sensor
Strainer
Heat exchange
inlet sensor
Outdoor unit / Single phase