Time program functions (Heating circuit 1 & 2, DHW, Cooling)
Several control programs are available for the
heating circuits and the production of DHW. They
are initiated in "Automatic" mode and control the
change in temperature levels (and therefore the
associated setpoints, reduced and comfort) via the
adjusted changeover times.
Changeover Points
LINE
HC1
HC2
4/DHW
500
520
560
501
521
561
502
522
562
503
523
563
504
524
564
505
525
565
506
526
566
Standard Program
LINE
516, 536, 576, 616
All time programs can be reset to factory settings.
Each time program has its own programming line
for this reset action.
Holidays
LINE
HC1
HC2
641
651
642
652
643
653
648
658
The holiday program enables changing the heating
circuits over to a selected operating level according
to the date (calendar).
Enter changeover times:
Changeover times can be adjusted in a combined
way, i.e., identical times for several days or distinct
times for certain days. Preselecting groups of days
(e.g., Mon...Fri and Sat...Sun) having the same
changeover times make adjustment of the
changeover program considerably shorter.
FUNCTION
5
600
Preselection
(Mo-Su / Mo-Fr / Sa – Su / Mo...Su)
st
601
1
phase on
st
602
1
phase off
nd
603
2
phase on
nd
604
2
phase off
rd
605
3
phase on
rd
606
3
phase off
FUNCTION
Default values
(No /Yes)
In this case, individual settings will be lost!
FUNCTION
Preselection
Period start (Day / Month)
Period end (Day / Month)
Operation level
Important:
The holiday program can be used only in the
automatic mode.
- (CS01 - 23) -
- (CS01 - 23) -
Control system