Fujitsu WGYA050DG6 Design & Technical Manual page 131

Hide thumbs Also See for WGYA050DG6:
Table of Contents

Advertisement

ACCESS
LINE
LEVEL
1620
I
24h / day: The temperature of the DHW is constantly maintained at the DHW comfort
setting.
Heating circuit time programme: The DHW is produced according to the programming
for the ambient temperature (with 1 hour in advance when switched on).
Programme 4 / DHW: The DHW programme is separate form the heating circuit
programme.
Off-peak tariff* : The electrical backup heating is only authorised to operate during the
off-peak period.
T'prog 4/DHW or low-tariff *: The electrical backup heating is authorised to operate
during the comfort period or off peak.
* - Connect the "Power Provider" contact to input EX2. In the case of a day /night contract,
the electric back-ups for the DHW tank are subject to the power supplier's tariffs. Switching
on the electric back-up for the DHW tank is only authorised during off-peak hours.
1640
I
1641
I
1642
S
1644
S
1645
S
1646
S
1647
S
1660
S
Swimming pool (Only with swimming pool kit option)
2055
U
2056
U
2057
S
2065
S
2080
S
2803
S
2843
S
2844
S
2862
S
2873
S
2882
S
2884
S
2916
S
FUNCTION
Release of DHW load
Legionella function
Legionella function periodically
Legionella function weekday
Legionella function time
Legionella funct setpoint
Legionella funct duration
Legionella funct circ pump
Legionella function weekday
Setpoint solar heating
Setpoint source heating
Swi diff source heating
Charging priority solar
Setpoint source heating
Heat pump
Overrun time cond pump
Compressor off time min
Switch-off temp max
Locking time stage 2 / mod
Compressor mod run time
Release integral electric flow
Release electric flow below OT
Electrical release - start-up with
outside temperature
Max setpoint HP DHW charg
- (CS01 - 15) -
- (CS01 - 15) -
SETTING RANGE
OR DISPLAY
24h / day
Heating circuit time programme
Programme 4 / DHW
Off-peak tariff (Off-peak)
Programme 4 / DHW
and Off-peak
Off, Periodically (depending line
setting 1641), Fixed weekday
(depending line setting 1642)
1 to 7
Monday, Tuesday,...
Off, On
Time program 3/HCP,
DHW release,
Time program 4/DHW,
Time program 5
8... 80 °C
8... 35 °C
0.5... 3 °C
Priority 1, Priority 2,
Priority 3
No, Yes
8...240s
0...120min
8...100°C
0...40min
10...600s
0...500°Cmin
-30...30°C
8... 80°C
FACTORY
SETTING
Programme
4 / DHW
Off
7
Saturday
Off
DHW release
26°C
22°C
0.5°C
Priority 1
Yes
240s
8min
75°C
5min
240s
100°Cmin
2°C
58°C
Control system

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents