21

SPECIFICATIONS

2-11

NOMINAL CAPACITY AND NOMINAL INPUT

Model name (Outdoor unit)
POWER SOURCE
Heating capacity
+7°C/+35°C
floor heating
Input power
COP
Heating capacity
+7°C/+45°C
Input power
floor heating
COP
Heating capacity
+2°C/+35°C
Input power
floor heating
COP
* Test conditions comply with EN14511-2
WO A060LFCA
Minimum
1.75
Nominal
4.50
kW
Maximum
7.02
0.996
Nominal
-
4.52
4.50
kW
Nominal
1.30
-
3.46
4.50
kW
Nominal
1.39
-
3.24
- (OU01 - 04) -
WO A080LFCA WO A100LFTA
1Ø 230V ~ 50Hz
1.75
1.75
6.00
7.50
7.83
9.20
1.41
1.84
4.27
4.08
5.10
6.20
1.50
1.87
3.40
3.31
4.95
5.65
1.53
1.78
3.24
3.17
Outdoor unit / Single phase
3.20
10.00
13.45
2.49
4.02
8.27
2.53
3.27
7.70
2.47
3.12