When assembling the pump unit in the sheet feed unit
- Position the pump unit so that the pump unit's pin fits in the groove "A" in the figure below.
- Confirm that the pump unit's bosses fit in the holes "B" in the figure below.
- Set the purge tube in place.
Check items after pump unit assembly in the sheet feed unit
Rotate the pump drive gear clockwise and counterclockwise, and confirm the following:
- The pump makes piston action properly at "A" in the figure below.
- The pump sensor lever operates properly (repeats movement shown in figures "Standby" and "Sensor ON" ).
Download Service Manual And Resetter Printer at http://printer1.blogspot.com
<Standby>
<Part 1: 3. REPAIR, 3-3, (1) to (3)>
<Sensor ON>