Valve Replacement - Regency L390PB Owners & Installation Manual

Table of Contents

Advertisement

MAINTENANCE
Before you begin:
* Shut off the gas supply to the unit.
Disconnect electrical supply to the unit.
Always let the appliance cool to room temperature before servicing.
Remove unit fl ue collars (see section in manual) slide unit out.
1. Disconnect the following from the valve:
1. DC sparker
2. Thermocouple
3. Thermopile leads
4. ON/OFF control
4
2. Disconnect the Gas Orifi ce supply line (5) from the outlet of the Gas
Valve.
48

VALVE REPLACEMENT

1
2
3
5
3. Disconnect the Pilot Supply Line (6) from the Gas Valve
6
4. Disconnect the Gas Supply Line (7) from the On/Off Safety Shut off
Valve.
7
5. Loosen 4 screws (8) that secure the Gas Valve Mounting bracket, slide
bracket up to release.
9
6. Remove valve from bracket by removing 4 screws (9).
7. Replace valve and reverse steps to reinstall.
390
L
8
390
PB-2 / HZI
PB-2 Direct Vent Gas Insert