GT Remote Receiver Components
1
946-680
GT remote control
Note: GT remote control installation must be completed prior to the unit
being installed.
1. Bring the TH and TP-TH wires around back of the unit to the right side -
where the valve is located.
2. Connect the TH/TP-TH wires from the harness to the valve terminals also
marked TH/TP-TH - locations as shown below.
TPTH Wire
3. Secure cable ties to the unit as shown by inserting cable ties into round
holes. There will be a total of 4 cable ties that need to be inserted into the
holes. (2 on the back and 2 on the left side located on the lower side of
the fi rebox).
390
390
L
PB-2 / HZI
PB-2 Direct Vent Gas Insert
GT REMOTE INSTALLATION
TH Wire
4. Bundle excess wires - with the exception of the wire marked receiver.
Receiver wire requires enough slack to reach the front left of the unit t
be connected to the receiver.
Secure wires with cable ties installed in previous step.
Additionally secure wires with a wire clip to be installed in location show
below.
Right
Wire Clip
Cable Tie
Cable Tie
4. Install receiver onto backing plate with 2 screws and plug in receiver w
.
5. Connect receiver wire from the wiring harness to the back side of the
remote receiver as shown below
8. Bundle excess receiver wire using a cable tie and secure to the front le
of the fi rebox as shown below.
INSTALLATION
Left
Cable Tie
19