Installation Checklist; Materials Required; Minimum Fireplace Dimensions - Regency L390PB Owners & Installation Manual

Table of Contents

Advertisement

INSTALLATION
INSTALLATION
CHECKLIST
Before installing vent system ensure that the damper plate is open and
secure to prevent the damper plate from falling down and crushing the liner.
The Regency Gas Insert is installed as listed.
1) Check all clearances to combustibles, (Refer to sections "Minimum
Fireplace Dimensions and Clearances to Combustibles)
2) Make the gas connection. (Refer to section "Gas Connection")
3) Install the two 3" fl ue liners (intake and exhaust) to the sliding connector
plate. (Refer to section "Flue Liner Installation.")
4) Slide the unit half way into the fi replace.
5) Pull the vent connector plate through the tapered brackets and fasten
to the front plate. Refer to section "Flue Liner Installation.")
6) Slide the unit fully into the fi replace. Level if necessary.
7) Test gas pressure (Refer to section "Gas Pipe Pressure Testing"). Check
aeration system (Refer to section "Gas Insert Aeration System").
8) Install standard and optional features. Refer to the following sections:
a. Brick Panels
b. Enamel Panels
c. Log Set
d. Glass Crystals
e. Stones
f. Low Profi le Faceplate
g. Optional Screen
h. Wall Thermostat
i. Remote Control
9) Final check: Before leaving this unit with the customer, the installer must
ensure that the appliance is fi ring correctly. This includes:
a) Clocking the appliance to ensure the correct fi ring rate.
b) Adjusting the primary air, if required, to ensure that the fl ame does
not carbon. See "Gas Insert Aeration System" section.
c) Ensuring that the appliance is venting correctly.

MATERIALS REQUIRED

No electrical power supply is required for the gas control to operate, however a
AA battery is required for the DC sparker. A 120 Volt AC power cord is hooked
up to the fan. Plug the 3 wire cord into a suitable receptacle. Do not cut the
ground terminal off under any circumstances. When connected with 120
volts, the appliance must be electrically grounded in accordance with local
codes, current version of CSA C22.1 (in Canada) or in the absence of local
codes, with the National Electrical Code ANSI/NFPA 70-1987.
10
MINIMUM FIREPLACE
DIMENSIONS
The minimum fi replace clearances & dimensions for the Regency gas insert
are shown in the following diagrams:
Max
Overall
Lentil Bar
Height
Depth
Depth
B
C
A
Low
10"
20"
16-
Profi le
1/8"
Face-
plate
B
390
L
Width
Width
Front
Width
(rear)
(front)*
Depth
(front)*
D
E
(prior to
G
(prior to
taper)
22"
32"
5-1/2"
33
3-1/2"
A
C
Side View
D
C
Example A
F
1
E
Top View
D
C
Example B
F
2 2 2
G
Top View
D
C
H
Top View
390
PB-2 / HZI
PB-2 Direct Vent Gas Insert
Front
Front
Depth
Depth
H
taper)
36"
Example C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hzi390pb

Table of Contents