INSTALLATION
GTM Remote Receiver Components
1
946-681
GTM remote control
1
946-683
Stepper Motor (NG) (sold separately)
(or)
946-984
Stepper Motor (LP) (sold separately)
Note: GTM remote control installation must be completed prior to the unit
being installed.
1. Bring the TH, TPTH, and Stepper motor wires around back of the unit to
the right side - where the valve is located.
2. Connect the TH/TP-TH wires from the harness to the valve terminals also
marked TH/TP-TH - locations as shown below.
3. Install stepper motor (installation instructions provided by SIT).
TPTH Wire
20

GTM REMOTE INSTALLATION

4. Connect the stepper motor wire (marked stepper) from the harness into
5. Secure cable ties to the unit as shown by inserting cable ties into round
6. Bundle excess wires - with the exception of the wire marked receiver.
TH Wire
the stepper motor wire on the motor.
holes. There will be a total of 4 cable ties that need to be inserted into th
holes. (2 on the back and 2 on the left side located on the lower side of
the fi rebox).
Receiver wire requires enough slack to reach the front left of the unit to
be connected to the receiver.
Secure wires with cable ties installed in previous step.
Additionally secure wires with a wire clip to be installed in location
shown below.
Right
Wire Clip
Cable Tie
Cable Tie
Receiver Wire
390
L
PB-2 / HZI
Left
Cable Tie
390