INSTALLATION
GTMF Remote Receiver Components
1
946-682
GTMF remote control
1
946-683
Stepper Motor (NG)
(or)
946-984
Stepper Motor (LP)
1
946-699
10 foot wiring harness package
(Discard existing 2ft wire harness)
10 foot power extension cord for Fan Control
Module
Note: GTMF remote control installation must be completed prior to the unit
being installed.
1. Remove heat shield from Fan Control Module and install to the left side
of the unit with 2 screws as shown below.
2. Bring the TH/TP-TH, and Stepper motor wires around back of the unit to
the right side - where the valve is located. All remaining wires from the
wiring harness must remain near the fan control module.
22

GTMF REMOTE INSTALLATION

3. Connect the TH/TP-TH wires from the harness to the valve terminals also
marked TH/TP-TH - locations as shown below.
4. Install stepper motor (installation instructions provided by SIT).
5. Connect the stepper motor wire (marked motor) from the harness into the
stepper motor wire on the motor.
6. Cut the cable tie to release the power cord bundled on the right side,
bring around to the back of the unit to the left side near the fan control
module.
7. Plug power cord into the outlet marked FAN on the fan control module.
8. Secure cable ties to the unit as shown by inserting cable ties into round
TPTH Wire
See below.
holes. There will be a total of 4 cable ties that need to be inserted into the
holes. (2 on the back and 2 on the left side located on the lower side of
the fi rebox).