Install Dimm Memory Modules - Intel P4304BT series Quick Installation User's Manual

Table of Contents

Advertisement

Processor, Heat Sink, Memory Installation
2b
Install Active Heat Sink(s)
CAUTION: The heat sink has
thermal interface material (TIM)
on the underside of it. Use
caution so that you do not
damage the thermal interface
material. Use gloves to avoid
sharp edges.
Use the following procedure to install an
active heat sink to your server board:
A
Make sure the screwdriver slot at
the top of each fastener is rotated
perpendicular to the blades of
the heat sink as shown.
2c

Install DIMM Memory Modules

DDR3 DIMM Memory Identification:
CAUTION: Observe normal ESD (ElectroStatic Discharge) procedures
to avoid possible damage to system components.
This server board supports up to 4 DDR3 1066/1333 ECC UDIMM.
Non-ECC memory is NOT supported by this server board.
DIMM
notch and
socket
bump must
align as
shown.
DDR3
Install DIMM Memory Modules ... Continued
Memory Type: Minimum of one 1 GB, DDR3
1066/1333 MHz ECC UDIMM.
Note: For additional memory configurations, see
the Techinical Product Specification on the Intel
Server Deployment Toolkit CD that accompanied
your Intel
Server Board S1200BT, or go to:
®
http://www.intel.com/support/motherboards/server.
Memory sizing and configuration is supported
only for qualified DIMMs approved by Intel
a list of supported memory, see the tested memory
list at
http://serverconfigurator.intel.com/default.aspx.
3
NOTE: Return to step
on page 2 when finish this section.
3
2
A
E
TIM
Other
Memory
Memory Configurations and Population Order:
®
. For
®
Intel
Server Board S1200BTL Shown
®
Note: Heatsink
styles may vary
1
4
C
E
To Install DIMMs:
CAUTION: Avoid touching contacts when handling or installing DIMMs.
A
Open both DIMM socket levers.
B
Note location of alignment notch.
C
Insert DIMM making sure the connector edge of the DIMM aligns correctly with the slot.
D
Push down firmly on the DIMM until it snaps into place and both levers close.
E
IMPORTANT! Visually check that each latch is fully closed and correctly engaged with
each DIMM edge slot.
C
E
D
A
DIMM A2
DIMM A1
DIMM B2
DIMM B1
Intel
6
B
Align heat sink with holes
in board and lower assembly
to board. Snaps go through
holes in server board.
Repeat B-D for each
fastener in the numerical
order shown at left.
D
Press downward
Fastener snaps
on top of cap.
into final position.
Plug the fan cable into the CPU fan header.
B
DIMM A2
DIMM A1
DIMM B2
DIMM B1
Server Board S1200BTS Shown
®

Advertisement

Table of Contents
loading