Ground Fault Circuit Interrupter (GFCI)

This generator has two types of Ground Fault Circuit Interrupter (GFCI)
systems, GFCI system ① and GFCI system ② .
GFCI System ①
(120V-30A, 120V/240V-30A, 120V/240V-37.5A RECEPTACLES)
If there is a ground-fault current from either A, B or C receptacle, it will
shut off the power to receptacles A, B, and C.
If this GFCI system ① activates, the AC circuit breaker will be
switched to OFF position and it will shut off power to all receptacles,
including GFCI system ② 120 V 20 A DUPLEX RECEPTACLES.
GFCI System ②
(120V-20A DUPLEX RECEPTACLE)
If there is a ground-fault current from either 120 V 20 A DUPLEX
RECEPTACLE, then the GFCI System ② will shut off the power to that
120 V 20 A DUPLEX RECEPTACLE. GFCI system ① will not be affected.
GFCI SYSTEM ①
(120V-30A, 120V/240V-30A, 120V/240 V-37.5 A RECEPTACLES)
AC CIRCUIT
BREAKER
RECEPTACLE A
(120/240 V 37.5 A)
RECEPTACLE B
(120/240 V 30 A)
CONTROLS & FEATURES
GFCI SYSTEM ②
(120V-20A DUPLEX RECEPTACLES)
RECEPTACLE C
(120 V 30 A)