6. Press the RESET button:
• The green indicator will light continuously.
• If the red indicator starts to blink continuously, contact an
authorized Honda generator dealer.
When the RESET button pops out or the green indicator does not lit
during operation:
• Unplug all appliances from the GFCI protected receptacle.
• Press the RESET button.
– If the GFCI cannot be reset, the GFCI is faulty. Contact an authorized
Honda generator dealer.
– If the RESET button extends, this usually indicates a faulty
power tool, appliance, or cord. If that occurs, perform operation
check steps 1 through 6 to verify that the GFCI is in proper
working order. If the GFCI tests correctly, then the fault is likely
to be in the power tool, appliance, or cord. Repair or replace the
faulty power tool, appliance, or cord before further use.
OPERATION
INDICATOR
RESET BUTTON