GENERATOR USE

To keep the generator always in top mechanical and electrical condition,
observe the following.
Combined load of the connected apparatus must not exceed the rated
capacity of the generator.
Rated capacity: 2800 VA
To prevent electrical shock from faulty appliances, the generator
should be grounded.
1 –

GROUND TERMINAL

– 1
Eco Throttle System
The Eco throttle system automatically reduces engine speed when all loads
are turned off or disconnected. When appliances are turned on or
reconnected, the engine returns to proper speed to power the electrical load.
ON:
Eco throttle system operates.
OFF:
Eco throttle system does not operate.
AC Application
1. Start the engine and make sure the output indicator (green) comes on.
2. Turn the Eco-throttle switch to the ON or OFF position.
1 –
ON

ECO THROTTLE SWITCH

OFF
– 2