Initial Use Instructions; Engine Oil - Honda EB10000 Owner's Manual

Hide thumbs Also See for EB10000:
Table of Contents

Advertisement

INITIAL USE INSTRUCTIONS

Engine Oil

The generator is shipped WITHOUT OIL in the engine.
1. Place the generator on a level surface.
2. Open the maintenance cover.
3. Remove the oil filler cap and oil level dipstick.
4. Add enough oil to bring the oil level to the upper limit mark on the
oil dipstick. SAE 10W-30 API service category SJ or later (or
equivalent) is recommended for general use; for additional
recommendations (see page 50).
Maximum oil capacity:
Without oil filter replacement: approximately 1.6 US qt (1.5 L)
With oil filter replacement: approximately 1.8 US qt (1.7 L)
Do not overfill the engine with oil. If the engine is overfilled, the
excess oil may be transferred to the air cleaner housing and air filter.
5. Reinstall the oil level dipstick and filler cap.
6. Close the maintenance cover.
MAINTENANCE COVER
100
UPPER LIMIT
LOWER LIMIT
OIL FILLER CAP
OIL LEVEL DIPSTICK

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents