OPERATION
GFCI System ①

(120V-30A, 120V/240V-30A, 120V/240V-37.5A Receptacles)

1. Unplug all tools and appliances from the generator.
2. Start the engine (see page 29).
3. Turn OFF the Auto Throttle switch (see page 30).
4. Turn the AC circuit breaker to the ON position.
GFCI SYSTEM ①
(120V-30A, 120V/240V-30A, 120V/240V-37.5A RECEPTACLES)
AUTO THROTTLE
SWITCH
120/240 V 37.5 A RECEPTACLE
5. Press the TEST button:
• The RESET button should pop out, and the AC circuit breaker
should switch to the OFF position.
• If the GFCI and AC circuit breaker do not function as described, take
the generator to an authorized Honda generator dealer for repair.
AC CIRCUIT BREAKER
34
AC CIRCUIT BREAKER
ON
120/240 V 30 A RECEPTACLE
RESET BUTTON
OFF
RESET BUTTON
TEST BUTTON
120 V 30 A RECEPTACLE
TEST BUTTON