Component Testing Control Board - Viking VCFF136D Service Manual

Freestanding french door bottom-mount refrigerator/ freezer with dispenser
Hide thumbs Also See for VCFF136D:
Table of Contents

Advertisement

Service Diagnostics and Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power to unit using power
switch before servicing. After servicing, reconnect power using power switch.
Component Testing
The unit has a main control board and UI (dispenser) board that control functions of the respective
refrigerator/freezer compartment. Components can be diagnosed via these boards. With the board accessed
(refer to control board access procedure, page 71 and dispenser board access procedure, page 67), the
following can be measured:
Component Testing–Control Board
Component
Condenser Motor
Defrost Terminator
Evaporator Fan Motor
(120 volt)
Evaporator Fan
Damper
Damper Switch
Refrigerator Lights
Refrigerator Light Switch
(N.C.)
Refrigerator Interlock Switch
(N.O.)
Freezer Light Switch
Freezer Lights
Ice Maker Switch
Ice Maker
Ice Auger
Icemaker Thermistor
Freezer Thermistor
Refrigerator Thermistor
Ice Fan
© 2010 Viking Preferred Service
WARNING
Board
Test Point
Control
J1-1 (Blue) to J1-8 (White)
Control
J1-2 (Brown) to J2-5 (Orange)
Control
J1-3 (Black) to J1-8 (white)
Control
J6-5 (Black/Yellow) to J6-1 (Black/Green)
Control
J1-4 (Red) to J1-7 (Yellow/Red)
Control
J1-4 (Red) to J2-4 (Blue/Red)
Control
J1-6 (Red/White) neutral to J1-4 (Red) Line
Conditions: Either fresh food door must be
open and power disconnected.
Control
J2-1 (Tan/Red) to J1-4 (red).
Conditions: Either fresh food door must be
open and power disconnected
Control
J2-10 (Black/Red) to J1-4 (Red)
Control
J1-4 (Red) to J2-6 (Gray/White).
Control
J1-6 (Red/White) to J2-6 (Gray/White)
Control
J2-8 Violet) to J2-2 (Gray)
Control
J2-8 (Yellow) to J1-8 (White)
Control
J2-9 (Pink) to J1-8 (White)
Control
J3-4 (White/Black) to J3-5 (White/Orange)
Control
J3-2 (White/Yellow) to J3-5 (White/Orange)
Control
J3-1 (White/Blue) to J3-5 (White/Orange)
Control
J6-2 (Red/Black) to J6-4(Blue/Black)
Reading
4.7
Open 0
Closed
*Depends on coil temperature
1637
6.54K
2.4K
0 switch closed
switch open
8.8
0 door open
door closed
0 door closed
door open
0 door closed
door open
25.1
0 switch on
switch off
266
4.4
9.31K @ room temperature
9.38K
7.63K
26.8K
38

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ddff136d

Table of Contents