202 Default Defrost Operation

Press the "UR" keypad or "LR" keypad to toggle defrost operation from normal adaptive defrost (off position)
to minimum time between defrosts (on position).
Press either
button to
toggle through
test cycles
203 Show Temperature Set points–Disregard this Test (unit will not display actual-temperature only set
temperature).

211 Fresh Food Temperature Offsets

Press the "UR" keypad or "LR" keypad to toggle calibration of fresh food temperature plus or minus in 1°F
increments up to 6°F.
Press either
button to
toggle through
test cycles
Note: Temperature will read in fahrenheit regardless of what current temperature scale is being used.

212 Freezer Temperature Offsets

Press the "UR" keypad or "LR" keypad to toggle calibration of freezer temperature plus or minus 1°F in
increments up to 6°F.
Press either
button to
toggle through
test cycles
Note: Temperature will read in fahrenheit regardless of what current temperature scale is being used.
© 2010 Viking Preferred Service
202
OFF
211
1
212
1
Press either
button to
cycle normal
adaptive defrost (OFF)
to minimum
time between
defrosts (ON)
Press either
button to change
calibration of fresh
food temperature
plus or minus in
1˚ increments
Press either
button to change
calibration of freezer
temperature plus
or minus in
1˚ increments