Download  Print this page

Component Testing-high Voltage Board - Viking VCSB542 Service Manual

Built-in side-by-side refrigerator/freezer.
Hide thumbs

Advertisement

Service Diagnostics and Procedures-Disassembly
Component Testing-- - High Voltage Board
High Voltage Board
Component
Refrigerator/Condensate Fans
Evaporator Fans
L1
Compressor/Condensor Fan
Defrost Terminator (Open)
Defrost Terminator (Closed)
Defrost Heater - Out
Ref Door Switch
Freezer Door Switch
Neutral In
Line In
Ground
Neutral in - Lights
Neutral out - Lights
Pocket heater
(See Note below)
NOTE:
On models built after 5/19/2010, the built in pocket heater
is connected to E14. When the Compressor/Condenser
relay is de-energized, 115 Volts is supplied to Terminal 14.
E14 is wired to the N.C contact in the relay. When the
Relay is energized; power is removed from the heater.
© 2010 Viking Preferred Service
Test Point
Reading
E1 - E11
24 VDC
E2 - E9
115 VAC
E3 - E9
115 VAC
E4 - E9
115 VAC
E5 - E9
0 VAC
E5 - E9
115 VAC
E6 - E9
115 VAC
E7 - E9
115 VAC
E8 - E9
115 VAC
E9 - E10
115 VAC
E10 - E9
115 VAC
E11
N/A
E12 - E10
115 VAC
E13 - E10
115 VAC
E14 - E9
115 VAC
E11 Ground
E1 Refrigerator /
Condensate Fans
E4 Compressor
E14 Pocket heater
E3 Line In-115 VAC
E2 Evaporator fan
E7 Fresh F door SW
E8 Freezer door SW
E9 Neutral
E10 Line in –115 VAC
E5 Defrost Terminator
E6 Defrost Heater
E12 Neutral In
E12 Light relay
46

Advertisement

Table of Contents

   Related Manuals for Viking VCSB542

Comments to this Manuals

Symbols: 0
Latest comments: