Electrical Wiring Connection; Cooling Only - Acson 5CE 35E Installation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
IMPORTANT: * These values are for information only. They should be checked and selected to comply with local and/or
national codes and regulations. They are also subject to the type of installation and size of conductors.

Cooling Only

(5)CE35/40E Vs (5)SL35/40C (1 PH)
L
Indoor Unit
N
Terminal
Block
COMP
!
The electrical power must be provided with
protection devices (circuit breaker or fuse) with
double pole separation system (phase + neutral)
with minimum contact gap of 3.0mm.
Model
Voltage range
Recommended fuse* (A)
Power supply cable size* (mm
Number of conductors
Interconnection cable size* (mm
Number of conductors
(5)CE40E Vs (5)SL40C (3 PH)
5CE35E Vs 5SL35C (3 PH)
Indoor Unit
Terminal
Block
!
The electrical power must be provided with
protection devices (circuit breaker or fuse) with
double pole separation system (phase + neutral)
with minimum contact gap of 3.0mm.

ELECTRICAL WIRING CONNECTION

Interconnection Cable
Indoor
Outdoor
2
)
2
)
COMP
Interconnection Cable
L
N
Power Supply Cable
(5)CE35E
(5)SL35C
220-240V/1Ph/50Hz +
30
4
3
1.5
4
Power Supply Cable
1-10
N
L
Outdoor Unit
Terminal
COMP
Block
R
S
N
L
(5)CE40E
(5)SL40C
!
30
4
3
1.5
4
COMP
Outdoor Unit
L
Terminal
N
Block
R
S
T
N