Russound Firmware Update Utility Install - Russound MCA-C5 Service Manual

8 source multizone controlle amplifier
Hide thumbs Also See for MCA-C5:
Table of Contents

Advertisement

Russound Firmware Update Utility Install

1. Open the "Russound Firmware Update Utility".
Turn on the MCA-C5.
2. Select the "Com Port" your computer is using in the "Port" window.
Select "C5 (small)" in the Product window.
Navigate to the current MCA-C5*.bin file after clicking ... button.
Click the "Erase" button.
You will see the "Erase Target" dialog. Set Keypad ID value to 127.
Click the "Erase" button.
3. The RFU Utility will display "Erase Internal" under the Erase button then
The RFU Utility will display "Erase External low" and then
The RFU Utility will display "Erase Done".
Note: Be patient this will take a little time.
4. Click the "Enable Download" button.
The RFU Utility will display "Downloading External low" then
The RFU Utility will display "Downloading Internal" then
The RFU Utility will display "Update Complete.".
Note: Be patient this will take approximately 10 minutes.
5. Turn off the MCA-C5.
6. Close "Russound Firmware Update Utility".
7. Continue by performing the
"Tuner MCU Firmware"
MCA-C5 Test Procedure
Rev 1.5
Page 22 of 78
section.